A technique for rapid single-echo spin-echo T2 mapping

✍ Scribed by Marshall S. Sussman; Logi Vidarsson; John M. Pauly; Hai-Ling Margaret Cheng


Publisher
John Wiley and Sons
Year
2010
Tongue
English
Weight
646 KB
Volume
64
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A rapid technique for mapping of T~2~ relaxation times is presented. The method is based on the conventional single‐echo spin echo approach but uses a much shorter pulse repetition time to accelerate data acquisition. The premise of the new method is the use of a constant difference between the echo time and pulse repetition time, which removes the conventional and restrictive requirement of pulse repetition time ≫ T~1~. Theoretical and simulation investigations were performed to evaluate the criteria for accurate T~2~ measurements. Measured T~2~s were shown to be within 1% error as long as the key criterion of pulse repetition time/T~2~ ≥3 is met. Strictly, a second condition of echo time/T~1~ ≪ 1 is also required. However, violations of this condition were found to have minimal impact in most clinical scenarios. Validation was conducted in phantoms and in vivo T~2~ mapping of healthy cartilage and brain. The proposed method offers all the advantages of single‐echo spin echo imaging (e.g., immunity to stimulated echo effects, robustness to static field inhomogeneity, flexibility in the number and choice of echo times) in a considerably reduced amount of time and is readily implemented on any clinical scanner. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Comparison of conventional single echo a
✍ Gary P. Liney; Adrian J. Knowles; David J. Manton; Lindsay W. Turnbull; Stephen 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 552 KB

## Abstract The accuracy of water T2 maps generated from a fast spin‐echo (FSE) sequence was compared with data obtained by conventional single and multi‐echo spin‐echo pulse sequences using a commercial gel phantom. Spatially localized stimulated echo acquisition mode (STEAM) proton spectroscopy w

Fast spin-echo triple-echo dixon (fTED)
✍ Jingfei Ma; Jong Bum Son; Yuxiang Zhou; Huong Le-Petross; Haesun Choi 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 289 KB

## Abstract Previously published fast spin‐echo (FSE) implementations of a Dixon method for water and fat separation all require multiple scans and thus a relatively long scan time. Further, the minimum echo spacing (esp), a time critical for FSE image quality and scan efficiency, often needs to be

Comparison of T2-weighted spin-echo and
✍ Erin C. Prenger; William W. Beckett; Spyros S. Kollias; William S. Ball Jr 📂 Article 📅 1994 🏛 John Wiley and Sons 🌐 English ⚖ 661 KB

## Abstract To evaluate T2‐weighted fast spin‐echo (FSE) and conventional spin‐echo (CSE) magnetic resonance (MR) techniques in the assessment of brain myelination, 100 consecutive pediatric patients were imaged prospectively with both CSE and FSE sequences. All patients underwent a routine MR exam

A new T2 preparation technique for ultra
✍ Todd Parrish; Xiaoping Hu 📂 Article 📅 1994 🏛 John Wiley and Sons 🌐 English ⚖ 586 KB

## Abstract The __T__~2~, contrast in images obtained with driven equilibrium (90°~x~−180°~x~−90°~x~) prepared ultrafast gradient‐echo sequences is compromised by the longitudinal magnetization build‐up after the second 90°~x~ pulse, which does not carry __T__~2~ information. This paper describes a