A system for simultaneous exposure of small animals to 50-Hz electric and magnetic fields
โ Scribed by J. W. Baum; A. V. Kuehner; R. D. Benz; A. L. Carsten
- Publisher
- John Wiley and Sons
- Year
- 1991
- Tongue
- English
- Weight
- 950 KB
- Volume
- 12
- Category
- Article
- ISSN
- 0197-8462
No coin nor oath required. For personal study only.
โฆ Synopsis
Equipment designed for simultaneous exposure of rodents to 60-Hz electric and magnetic fields is described. Three identical systems were constructed, each capable of continuous exposure of 256 rats or 640 mice to a nominal electric field at <50 kV/m, and to horizontal and vertical magnetic fields at <1 mT. Design features, construction details, and results of various tests of the systems are described. Tests were made: of phase relations between electric and magnetic fields; of uniformity of electric and magnetic fields; of changes across time in electric-field intensity as a result of animals' soiling of cages and various washing routines; of resistance of bedding material during humid and dry conditions; and of acoustic noise due to background, to field-generation equipment, and to air conditioning equipment. The results demonstrated that fields were effectively generated but that significant and troublesome changes in electric-field intensity occurred because of cage-soiling. However, when cages were frequently cleaned, field intensities were consistent from one exposure to another.
๐ SIMILAR VOLUMES
We exposed pigtailed macaques (Macaca nernesfrina) to electric (E) and magnetic (B) fields at strengths of 3 kV/m and 0.1 G , 10 kV/m and 0.3 G, and 30 kV/m and 0.9 G for three 21 day segments. These three exposure segments were preceded and followed by 21 day sham exposure segments. Additional anim
In recent years, with the availability of high resolution models of the human body, numerical computations of induced electric fields and currents have been made in more than one laboratory for various exposure conditions. Despite the verification of computational methods, questions are often asked
Chinese hamster ovary (CHO) cells were exposed for 1 h to 60-Hz magnetic fields (0.1 or 2 mT), electric fields (1 or 38 V/m), or to combined magnetic and electric fields (2 mT and 38 V/m, respectively). Following exposure, the cells were lysed, and the DNA was analyzed for the presence of single-str
## Background: Epidemiological studies have inconsistently demonstrated a positive relationship between magnetic and/or electric fields and leukemia. although exposure to both 60 hz electric and magnetic fields can be characterized in many ways, to date, risk assessment has been performed by using