𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A single, selective and simple validated method for simultaneous estimation of amiloride and hydrochlorothiazide in human plasma by liquid chromatography–tandem mass spectrometry

✍ Scribed by Arvind G. Jangid; Rajesh H. Tale; Vikas V. Vaidya


Publisher
John Wiley and Sons
Year
2011
Tongue
English
Weight
159 KB
Volume
26
Category
Article
ISSN
0269-3879

No coin nor oath required. For personal study only.


📜 SIMILAR VOLUMES


Sensitive liquid chromatography–tandem m
✍ N. V. S. Ramakrishna; K. N. Vishwottam; S. Manoj; M. Koteshwara; S. Wishu; D. P. 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 134 KB 👁 2 views

A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of hydrochlorothiazide (I), a common diuretic and anti-hypertensive agent. The analyte and internal standard, tamsulosin (II) were extracted by liquid-liquid e

A simple, selective and rapid validated
✍ Arvind G. Jangid; Ashutosh M. Pudage; Santosh S. Joshi; Pramod N. Pabrekar; Raje 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 262 KB 👁 2 views

## Abstract A rapid, simple and specific method for estimation of anastrazole in human plasma was validated using letrozole as internal standard. The analyte and internal standard were extracted from plasma using simple solid‐phase extraction. The compound were separated on a reverse‐phase column w

Simultaneous determination of chlorpheni
✍ Xiaoyan Chen; Yong Zhang; Dafang Zhong 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 107 KB 👁 2 views

## Abstract A sensitive and specific procedure for simultaneous quantitation of chlorpheniramine and pseudoephedrine in human plasma has been developed and validated. Analytes were extracted from plasma samples by liquid–liquid extraction, separated on a Diamonsil C~18~ column (250 × 4.6 mm i.d.) an

Simultaneous determination of metformin
✍ Cun-Gang Ding; Zhen Zhou; Qing-Hua Ge; Xiao-Jin Zhi; Li-Li Ma 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 293 KB 👁 2 views

## Abstract A method has been developed for the simultaneous quantification of metformin (I) and glipizide (II) in human plasma. It is based on high‐performance liquid chromatography with electrospray ionization tandem mass (LC‐ESI‐MS/MS) spectrometric detection in positive ionization mode. Phenfor

Rapid and sensitive liquid chromatograph
✍ Jignesh Bhatt; Arvind Jangid; Bhavin Shah; Raghavendra Shetty; Sandeep Kambli; G 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 109 KB 👁 2 views

## Abstract A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method has been developed and validated for the estimation of nicorandil in human plasma. Nicorandil was extracted from human plasma using solid‐phase extraction technique. Imipramine was used as the interna