𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A simple method for calculating enantiomer ratio and equilibrium constants in biocatalytic resolutions

✍ Scribed by Henrik W. Anthonsen; Bård Helge Hoff; Thorleif Anthonsen


Publisher
Elsevier Science
Year
1995
Tongue
English
Weight
370 KB
Volume
6
Category
Article
ISSN
0957-4166

No coin nor oath required. For personal study only.

✦ Synopsis


A computer programme for determination of equilibrium constant (K) and enantiomer ratio (E) in biocatalytic resolutions has been developed. The programme utilises experimental data, ees and eep measured at more than one conversion, and determines both K and E no matter whether the reaction is irreversible (K=0) or reversible (K>0). An estimation of errors in the calculations indicates that errors in E does not show a Gaussian distribution, while errors in K does. The usefulness of the programme has been tested in a lipase-catalysed transesterification of 1-phenoxy-2-propanol at various concentrations of acyl donor, with different solvents and at different water activities.


📜 SIMILAR VOLUMES


A simple method for calculating reliable
✍ John Mullay 📂 Article 📅 1988 🏛 John Wiley and Sons 🌐 English ⚖ 689 KB

Modifications are made to a previously developed scheme for calculating atomic charge which uses orbital electronegativity and which requires minimal calculational effort. The introduced changes are a result of deficiencies noted in the earlier method which were due to an inadequate accounting of ef

A simple method for calculating atomic c
✍ John Mullay 📂 Article 📅 1991 🏛 John Wiley and Sons 🌐 English ⚖ 722 KB

A previously developed method for calculating atomic charge in neutral molecules is modified so as to account for charged molecular species. The method is based on the orbital electronegativity (EN) concept and utilizes an EN equalization principal. Since only one linear equation is required per bon

Determination of the Donnan effect in eq
✍ Peter Suter; Jurg P. Rosenbusch 📂 Article 📅 1977 🏛 Elsevier Science 🌐 English ⚖ 375 KB

Radioactive cesium ions have been used as indicators for the unequal distribution of electrolytes in two-compartment systems which contain nondiffusible macroions in one of the compartments. This method allows the precise determination of the Donnan ratio under conditions in which binding studies of

Reference deconvolution: A simple and ef
✍ Metz, K. R. ;Lam, M. M. ;Webb, A. G. 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 404 KB

Linewidths and line shapes are key criteria determining the utility of a ( ) nuclear magnetic resonance NMR spectrum, and considerable effort is usually devoted to ( ) shimming the magnetic field B to ensure optimum resolution. However, even if the 0 external field is almost perfectly homogeneous, t