A simple calibration of a whole-body counter for the measurement of total body potassium in humans

โœ Scribed by M.S. Abdel-Wahab; S.K. Youssef; A.M. Aly; S.A. El-Fiki; N. El-Enany; Magda T. Abbas


Publisher
Elsevier Science
Year
1992
Weight
268 KB
Volume
43
Category
Article
ISSN
0883-2889

No coin nor oath required. For personal study only.

โœฆ Synopsis


A simple calibration procedure for the Inshas whole body counter for evaluating total body potassium has been adopted. More than 120 Egyptian employees in the Nuclear Research Center (N.R.C.) were studied for their total body potassium (TBK). The potassium values were found to have an average of 2.85 +/- 0.57 g K kg-1 body weight for males and 2.62 +/- 0.52 g K kg-1 for females, which are higher than the recommended value given for reference man by ICRP. The TBK varied directly with body build index and is slightly sex dependent.


๐Ÿ“œ SIMILAR VOLUMES


Whole-body bone scintigraphy provides a
โœ Shelby Addison; R. Edward Coleman; Sheng Feng; Gary McDaniel; Virginia Byers Kra ๐Ÿ“‚ Article ๐Ÿ“… 2009 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 116 KB ๐Ÿ‘ 1 views

## Abstract ## Objective To evaluate the association of serum and synovial fluid cartilage oligomeric matrix protein (COMP) with systemic and local measures of osteoarthritis (OA) activity by bone scintigraphy. ## Methods Samples of serum and knee joint synovial fluid (275 knees) were obtained f

A simple method for the quantitation of
โœ Alain Schweitzer; Alfred Fahr; Werner Niederberger ๐Ÿ“‚ Article ๐Ÿ“… 1987 ๐Ÿ› Elsevier Science โš– 561 KB

A simple method for the quantitation of 14C-whole-body autoradiograms by comparative densitometry is described. If processed under the same conditions as the samples of tissues to be investigated, a radioactive blood scale can be used as standard, with the exception of samples from bones, eyes and f

The effect of frequency and grounding on
โœ Dr. Douglas A. Hill ๐Ÿ“‚ Article ๐Ÿ“… 1984 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 821 KB

The radiofrequency absorption rates of five male human volunteers have been measured from 3 to 41 MHz. The subjects were exposed at about 10 pW/cm2 inside a very large transverse electromagnetic (TEM) cell and never absorbed more than 1 W. Both the EKH and EHK orientations were employed under both f

Variation in thickness of the large cryo
โœ Tsunao Ito; A. Bertrand Brill ๐Ÿ“‚ Article ๐Ÿ“… 1991 ๐Ÿ› Elsevier Science โš– 644 KB

A method to assess variation in thickness of the large cryosections for whole-body autoradiography (WBARG) was described, and the degree of intraslice and interslice variations were determined for our cryomicrotome system (LKB PMV-2250). Intraslice variation in thickness of the 180 x 80 mm cryosecti