## Abstract A rapid and sensitive liquid chromatographyโtandem mass spectrometry (LCโMS/MS) method has been developed and validated for the estimation of amlodipine in human plasma. Amlodipine was extracted from human plasma by using a solidโphase extraction technique. Imipramine was used as the in
A rapid and sensitive LC-MS/MS method for determination of coenzyme Q10 in tobacco (Nicotiana tabacum L.) leaves
โ Scribed by Yuangang Zu; Chunjian Zhao; Chunying Li; Lin Zhang
- Publisher
- John Wiley and Sons
- Year
- 2006
- Tongue
- English
- Weight
- 447 KB
- Volume
- 29
- Category
- Article
- ISSN
- 1615-9306
No coin nor oath required. For personal study only.
โฆ Synopsis
A rapid and sensitive LC-MS/MS method for determination of coenzyme Q 10 in tobacco (Nicotiana tabacum L.) leaves A rapid and sensitive liquid chromatography-tandem mass spectrometry method with multiple reaction monitoring has been proposed for the analysis of coenzyme Q 10 in (CoQ 10 ) tobacco leaves. The method used electrospray ionization with detection in positive ion mode. Sample pretreatment involved ultrasonic extraction of fresh tobacco leaves with anhydrous ethanol for 15 min and followed by extraction of the supernatant with hexane. The separation of CoQ 10 was performed on a Symmetry Shield RP18 column with a mixture of acetonitrile and isopropanol (8 : 7, v/v) containing 0.5% formic acid as mobile phase. Quantification of CoQ 10 was performed by the standard addition method. The limit of detection and limit of quantitation of CoQ 10 were, respectively, 1.2 ng/mL (S/N = 3) and 4.0 ng/mL (S/N = 10). The relative standard deviations of peak area were 0.91% and 1.21% for intra-day and inter-day, respectively. The recoveries of CoQ 10 ranged from 98.2 to 99.3% and the corresponding RSDs were less than 2.4%. Analysis took 5 min, making the method suitable for rapid determination of CoQ 10 in tobacco leaves. The proposed method has been successfully applied to the analysis of CoQ 10 in the leaves from eight varieties of tobacco.
๐ SIMILAR VOLUMES
In the production of radioligands for imaging low concentrations of target proteins (e.g. receptors or transporters) in human subjects with positron emission tomography, control of specific radioactivity is necessary for efficacy and safety. Such quality control requires a fast method to be availabl
## ABSTRACT A highly sensitive, specific and simple LCโMS/MS method was developed for the simultaneous estimation of dexlansoprazole (DEX) with 50โฮผL of human plasma using omeprazole as an internal standard (IS). The APIโ4000 LCโMS/MS was operated under multiple reactionโmonitoring mode using elect