A rabbit ear model for cold stress testing
β Scribed by Dr. Thomas L. Smith; Stanley Gordon; Martha B. Holden; Beth P. Smith; Gregory B. Russell; L. Andrew Koman
- Publisher
- John Wiley and Sons
- Year
- 1994
- Tongue
- English
- Weight
- 407 KB
- Volume
- 15
- Category
- Article
- ISSN
- 0738-1085
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
A rabbit ear model resembling the human digit was studied to determine the vascular response of the rabbit ear to a cold stress. Following moderate cooling (10 minutes at 5Β°β8Β°C), auricular blood flow and cutaneous perfusion were reduced. This decrease was reversed by 30 minutes of warming. The response in the rabbit ear to cold stress is similar to that of normal human digits. The similarities between the control of the circulation in human digits and rabbit ears may result from the similarities in digital and auricular vascular receptors and receptor subtypes. Verification of the rabbit model provides an experimental method for obtaining important data regarding digital pathophysiology and the treatment of cold intolerance. Further study with this model will provide clinically relevant information regarding the pathophysiology of digital thermoregulatory abnormalities. Β© 1994 WileyβLiss, Inc.
π SIMILAR VOLUMES
## Abstract A rabbit ear model has been developed in which arterial pressure, auricular blood flow conductance, and microvascular perfusion can be followed continuously in conscious animals. Conductance is measured with a transitβtime flow probe placed around the auricular artery, arterial pressure
## Abstract Conditions such as Raynaud's disease, cold intolerance following digit replantation, and reflex sympathetic dystrophy are all exacerbated by diminished blood flow in the digits. The rabbit ear, being similar to the human digit, is an excellent model for studying microvascular responses
The laser pulse doppler provides a noninvasive, reproducible method to measure the flux in distal capillary blood flow in a rabbit ear model. The distal capillary blood flow responds proportionally to changes in periarterial lidocaine concentration. The response is biphasic. Flow initially decreased