A Quartz Crystal Microbalance Study of the Adsorption of Asphaltenes and Resins onto a Hydrophilic Surface
✍ Scribed by Pontus Ekholm; Eva Blomberg; Per Claesson; Inge Harald Auflem; Johan Sjöblom; Anna Kornfeldt
- Publisher
- Elsevier Science
- Year
- 2002
- Tongue
- English
- Weight
- 259 KB
- Volume
- 247
- Category
- Article
- ISSN
- 0021-9797
No coin nor oath required. For personal study only.
✦ Synopsis
The adsorption of extracted and purified samples of asphaltenes and resins onto gold surfaces has been studied as a function of bulk concentration using a quartz crystal microbalance with dissipation measurements (QCM-D). With this device, which works equally well in transparent, opaque, and nontransparent samples, the adsorbed amount is measured through a change in resonant frequency of the quartz oscillator. The measured change in dissipation reports on changes in layer viscoelasticity and slip of the solvent at the surface. The results show that the adsorbed amount for resins from heptane corresponds to a rigidly attached monolayer. The adsorbed amount decreases with increasing amount of toluene in the solvent and is virtually zero in pure toluene. Asphaltenes, on the other hand, adsorb in large quantities and the mass and dissipation data demonstrate the presence of aggregates on the surface. The aggregates are firmly attached and cannot be removed by addition of resins. On the other hand, resins and asphaltenes associate in bulk liquid and the adsorption from mixtures containing both resins and asphaltenes is markedly different from that obtained from the pure components. Hence, we conclude that preformed resin aggregates adsorb to the surface. These results are compared and discussed in relation to adsorption from crude oil diluted in heptane/toluene mixtures.
📜 SIMILAR VOLUMES
## Abstract The immobilization of cell‐adhesive proteins onto titanium implants improves biological response at the implant–tissue interface. Previous studies demonstrated the easy and direct attachment of fibronectin onto titanium with the use of a 2,2,2‐trifluoroethanesulfonyl chloride (tresyl ch
The ultrathin polymer films that were composed of biodegradable and naturally occurring chitosan and poly(␥-benzylglutamate) were stably deposited onto a quartz crystal microbalance (QCM) by alternate immersion of a QCM from their aqueous solutions in the presence of water-soluble organic solvents a
## Abstract Poly(vinylidene fluoride) (PVDF) was deposited onto a quartz crystal microbalance (QCM), using a standard Langmuir–Blodgett (LB) thin film deposition procedure. QCM technique was used to monitor the reproducibility of the LB film monolayer, and the fabricated QCM sensor was employed to