A quantitative study of factors affecting in vivo bioluminescence imaging
β Scribed by Kemi Cui; Xiaoyin Xu; Hong Zhao; Stephen T. C. Wong
- Publisher
- John Wiley and Sons
- Year
- 2008
- Tongue
- English
- Weight
- 153 KB
- Volume
- 23
- Category
- Article
- ISSN
- 1522-7235
- DOI
- 10.1002/bio.1032
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
In vivo bioluminescence imaging (BLI) has the advantages of high sensitivity and low background. By counting the number of photons emitted from a specimen, BLI can quantify biological events such as tumour growth, gene expression and drug response. The intensities and kinetics of the BL signal are affected by many factors and may confound the quantitative results acquired from consecutive imaging sessions or different specimens. We used three different mouse models of tumours to examine whether anaesthetics, positioning and tumour growth may affect the consistency of the BL signal. The results showed that BLI signal could be affected by different anaesthetics and repetitive positioning. Using the same anaesthetics produced consistent peak times, while other factors were held constant. However, as the tumours grew the peak times shifted and the time course of BL signals had different shapes, depending on the positioning of the mice. The data indicate that a carefully designed BLI experiment is required to generate optimal and consistent results. Copyright Β© 2008 John Wiley & Sons, Ltd.
π SIMILAR VOLUMES
## Abstract ## Purpose To determine whether there are differences in increase in longitudinal relaxation rate (ΞR1) in the myocardium between bolus administration of Mn^2+^ ions during rest and during dobutamineβinduced stress and, additionally, to determine whether there are differences in ΞR1 be
## Abstract Nerve guides seeded with Schwann cells (SCs) promote axonal regeneration in peripheral nerve lesions. We examined the applicability of bioluminescent imaging (BLI) for monitoring the fate of SCs in nerve guides after implantation. Rat SCs were transfected with the firefly luciferase (Fl
A study was undertaken to evaluate the limitations of abdominal sonography in a group of predominantly elderly patients. In the majority of patients (98%) sonography, using 3.5 MHz and 5 MHz array transducers permitted visualization of the major abdominal organs with image quality sufficient for def
## Abstract Postβarthroplasty infections are a devastating problem in orthopaedic surgery. While acute infections can be treated with a single stage washout and liner exchange, chronic infections lead to multiple reoperations, prolonged antibiotic courses, extended disability, and worse clinical ou