𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A new fast and unsynchronized method for MRI of viscoelastic properties of soft tissues

✍ Scribed by Czeslaw J. Lewa; Muriel Roth; Lionel Nicol; Jean-Michel Franconi; Jacques D. de Certaines


Publisher
John Wiley and Sons
Year
2000
Tongue
English
Weight
404 KB
Volume
12
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.


πŸ“œ SIMILAR VOLUMES


New macromolecular polymeric MRI contras
✍ Clemens C. Cyran; Yanjun Fu; Hans-Juergen Raatschen; Victor Rogut; Bundit Chaopa πŸ“‚ Article πŸ“… 2008 πŸ› John Wiley and Sons 🌐 English βš– 401 KB

## Abstract ## Purpose To compare three new macromolecular polyethylene glycol (PEG) ‐core dendrimeric gadolinium(Gd)‐based MRI contrast agents for their applicability in quantitative assays of endothelial leakiness and tissue vascular density for the differentiation of cancer from normal soft tis

ChemInform Abstract: A New Method for Fa
✍ Ming Zhang; Lydia E. Kavraki πŸ“‚ Article πŸ“… 2010 πŸ› John Wiley and Sons βš– 24 KB πŸ‘ 1 views

## Abstract ChemInform is a weekly Abstracting Service, delivering concise information at a glance that was extracted from about 100 leading journals. To access a ChemInform Abstract of an article which was published elsewhere, please select a β€œFull Text” option. The original article is trackable v

Dynamic Aspects of Electrophoresis and E
✍ M. Minor; A.J. van der Linde; H.P. van Leeuwen; J. Lyklema πŸ“‚ Article πŸ“… 1997 πŸ› Elsevier Science 🌐 English βš– 171 KB

ture much greater than the double-layer thickness k 01 ). Po-Measuring the dc electrophoretic mobility in a microelectropholarization of the double layer was not taken into account. retic setup is traditionally performed at the stationary levels where In 1948, Henry (4) and Booth (5) independently

A new method for proton detection of H21
✍ Itamar Ronen; Gil Navon πŸ“‚ Article πŸ“… 1994 πŸ› John Wiley and Sons 🌐 English βš– 444 KB

## Abstract A method is presented for the sensitive detection of minute amounts of H~2~^17^O. The method is based on the increase of the T~2~ of the water protons following an irradiation of the ~17~O resonance frequency, due to the partial or full decoupling of the ^1^H‐^17^O spin‐spin interaction

RAPIDβ€”A new method for fast imaging usin
✍ William M. Brooks; Ian M. Brereton; David M. Doddrell πŸ“‚ Article πŸ“… 1987 πŸ› John Wiley and Sons 🌐 English βš– 286 KB

A single slice of z-magnetization is used to generate high-speed images. The slice selection step is achieved using two sin-sinc pulses. This procedure eliminates the need for continual slice gradient reversal, a requirement for the FLASH technique. The RAPID imaging method has less inherent T1 and/