𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A new design of the flow cuvette and optical set-up for the scanning flow cytometer

✍ Scribed by Juhani T. Soini; Andrei V. Chernyshev; Pekka E. Hänninen; Erkki Soini; Valeri P. Maltsev


Publisher
John Wiley and Sons
Year
1998
Tongue
English
Weight
133 KB
Volume
31
Category
Article
ISSN
0196-4763

No coin nor oath required. For personal study only.

✦ Synopsis


We introduce a new design for the optical cuvette and a new optical lay-out for the Scanning Flow Cytometer (SFC) that permits measurement of the angular dependency of the scattered light from individual moving particles. The improved optical scheme of the SFC allows measurement of the angular scattering pattern of individual particles at polar angles from 10 degrees to 120 degrees with integration at azimuthal angles from 0 degrees to 360 degrees and with angular resolution of better than 0.5 degrees. The performance of the SFC is demonstrated using certified polystyrene particles as reference material The aim of this work is to develop a flow cytometer, which, by recording the entire light scattering pattern of individual biological particles, would provide more information about the particle structure than the ordinary wide angle, forward and side scattering concepts.


📜 SIMILAR VOLUMES


Comparison of flow and laser scanning cy
✍ David A. Rew; Louise J. Reeve; George D. Wilson 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 128 KB 👁 1 views

The introduction of the laser scanning cytometer offers new capabilities in cell proliferation research, through its capacity for validation of each and every cell event through direct visualization on the microscope slide. In this study, we report a direct comparison of proliferation data derived f

A new sensitive flow-injection chemilumi
✍ Yu-Hai Tang; Nan-Nan Wang; Xun-Yu Xiong; Feng-Mei Xiong; Si-Juan Sun 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 221 KB 👁 1 views

## Abstract Based on the chemiluminescence (CL) intensity generated from the potassium ferricyanide [K~3~Fe(CN)~6~]–rhodamine 6G system in sodium hydroxide (NaOH) medium, a new sensitive flow‐injection chemiluminescence (FI–CL) method has been developed, validated and applied for the determination

A patient flow perspective of U.K. healt
✍ Eric Wolstenholme 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 261 KB 👁 1 views

This article applies system dynamics to the development of national policy guidelines for the U.K. health service. A model of total patient ¯ow through the U.K. National Health Service is developed and used to test alternative major new structural initiatives for relieving pressure on health service