𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A method for correctly setting the rf flip angle

✍ Scribed by William H. Perman; Matt A. Bernstein; John C. Sandstrom


Publisher
John Wiley and Sons
Year
1989
Tongue
English
Weight
524 KB
Volume
9
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


setting the correct rf power levels to achieve YO" and 180" rf pulses for MR imaging is to peak the echo amplitude of a rf spin-echo sequence. The echo amplitude of this 01-201 pulse sequence is proportional to sin3( a) and has a relatively broad maximum. Recently another method for setting the rf flip angle by maximizing the ratio of the stimulated echo to the primary echo amplitudes (in a 3a sequence) demonstrated accuracy similar to that of the spin-echo method using a shorter repetition time. We present a new, more sensitive, and more accurate method for setting the correct rf power levels for YO" and 180" rf pulses. In this method, based upon the stimulated echo pulse sequence, we are able to accurately set the rfpower to within kO.1 dB by minimizing the signal amplitude of the third spin echo. This null method works for both selective and nonselective rfpulses of flip angle 90" or 180", allowing the user to accurately adjust the relative amplitudes of the four rfpulse types within a single pulse sequence.


πŸ“œ SIMILAR VOLUMES


Rapid methods for concurrent measurement
✍ Jung-Jiin Hsu; Greg Zaharchuk; Gary H. Glover πŸ“‚ Article πŸ“… 2009 πŸ› John Wiley and Sons 🌐 English βš– 301 KB

## Abstract Measuring both the flip angle (FA) and the longitudinal relaxation time __T__~1~ is essential in quantitative and longitudinal studies because the signal amplitude is dependent on these quantities. Conventional methods can only measure one of them at a time and require long scan times.

The flip-angle effect: A method for dete
✍ Peter M. Joseph; Ronald M. Summers πŸ“‚ Article πŸ“… 1987 πŸ› John Wiley and Sons 🌐 English βš– 664 KB

A method is presented for the detection of quadrupole splitting in tissue, where the spectral line splittings are typically unobservable. The method used is a study of the rate of rotation of the flip angle as a function of radiofrequency (rf) amplitude. Our results with samples of skeletal muscle a

Additive angle method for fast large-tip
✍ William A. Grissom; Chun-Yu Yip; Steven M. Wright; Jeffrey A. Fessler; Douglas C πŸ“‚ Article πŸ“… 2008 πŸ› John Wiley and Sons 🌐 English βš– 906 KB

## Abstract Current methods for parallel excitation RF pulse design are based on the small‐tip‐angle approximation, which provides a computationally efficient means of pulse calculation. In general, pulses designed with those methods are inaccurate when scaled to produce large‐tip angles, and metho

kT-points: Short three-dimensional tailo
✍ M. A. Cloos; N. Boulant; M. Luong; G. Ferrand; E. Giacomini; D. Le Bihan; A. Ama πŸ“‚ Article πŸ“… 2011 πŸ› John Wiley and Sons 🌐 English βš– 598 KB

## Abstract With Transmit SENSE, we demonstrate the feasibility of uniformly exciting a volume such as the human brain at 7T through the use of an original minimalist transmit __k__‐space coverage, referred to as β€œ__k__~T~‐points.” Radio‐frequency energy is deposited only at a limited number of __k