## Abstract A new method has been developed for fast image‐based measurements of the transmitted radiofrequency (RF) field. The method employs an actual flip‐angle imaging (AFI) pulse sequence that consists of two identical RF pulses followed by two delays of different duration (TR~1~ < TR~2~). Aft
Rapid methods for concurrent measurement of the RF-pulse flip angle and the longitudinal relaxation time
✍ Scribed by Jung-Jiin Hsu; Greg Zaharchuk; Gary H. Glover
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 301 KB
- Volume
- 61
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Measuring both the flip angle (FA) and the longitudinal relaxation time T~1~ is essential in quantitative and longitudinal studies because the signal amplitude is dependent on these quantities. Conventional methods can only measure one of them at a time and require long scan times. In this work, two mutually consistent methods are developed; each can acquire multislice data for determining both the FA and T~1~ in a scan time about half the time needed for a conventional FA measurement. On the basis of a recent development of longitudinal‐relaxation measurement (Hsu and Lowe, J Magn Reson 2004;169:270–278; Hsu and Glover, J Magn Reson 2006;181:98–106), one of the methods uses RF pulse trains of two FAs whereas the other uses pulse trains of different pulse spacing. When only the FA or T~1~ is needed, the present methods can still be faster than conventional methods for the needed quantity. In benchmarking with a uniform‐density sample, both methods generate precise T~1~ values independent of the FA chosen (except at and near 90°). In the demonstration with three normal volunteers at 3 T, the T~1~ values of frontal and occipital white matter, putamen, and caudate are compared; the T~1~ values are in agreement with literature values and the intrasubject deviation is 0.2%–2.8%. Magn Reson Med, 61:1319–1325, 2009. © 2009 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract A novel imaging method is presented, Flip Angle Variation for Offset of RF and Relaxation (FAVOR), for rapid and efficient measurement of rat lung ventilation using hyperpolarized helium‐3 (^3^He) gas. The FAVOR technique utilizes variable flip angles to remove the cumulative effect of
A fundamental problem in Fourier transform NMR spectroscopy is the calculation of observed resonance amplitudes for a repetitively pulsed sample, as first analyzed by Ernst and Anderson in 1966. Applications include determination of spin-lattice relaxation times (T 1 's) by progressive saturation an