𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A Highly Sensitive and Fast Nonradioactive Method for Detection of Polymerase Chain Reaction Products

✍ Scribed by K. Holmstrom; L. Rossen; O.F. Rasmussen


Publisher
Elsevier Science
Year
1993
Tongue
English
Weight
547 KB
Volume
209
Category
Article
ISSN
0003-2697

No coin nor oath required. For personal study only.

✦ Synopsis


A novel system for the detection of polymerase chain reaction (PCR) products has been developed. The system is based on a PCR in which one of the primers is biotinylated and digoxigenin-11-dUTP is incorporated during elongation. Biotinylated PCR products are captured on streptavidin-coated solid supports, and alkaline phosphatase conjugated to anti-digoxigenin antibody is subsequently bound to the incorporated digoxigenin. The detection may be obtained with colorimetric, fluorescent, or luminescent substrates for alkaline phosphatase. The detection system can be performed in microtiter plates allowing easy handling of multiple samples. The total assay time following the PCR is between 1 and 2 h dependent on the type of substrate and the type of solid support applied in the system. Within this period of time the system is capable of detecting 1 template in 29 cycles of PCR.


πŸ“œ SIMILAR VOLUMES


Development of a quadriplex polymerase c
✍ Panayotis Markoulatos; Vicky Samara; Nikolaos Siafakas; Elias Plakokefalos; Niki πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 126 KB πŸ‘ 1 views

The development of a quadriplex PCR method with amplification of HCMV in a single-step procedure using primers taken from four different regions of the viral genome is described. Different concentrations of dNTPs and MgCl 2 were assayed in order to optimize the constitution of the buffer for the mul

Polymerase chain reaction for rapid dete
✍ Dr. D. J. Morris; A. S. Bailey; R. J. Cooper; Dr. P. C. Turner; Dr. R. Jackson; πŸ“‚ Article πŸ“… 1995 πŸ› John Wiley and Sons 🌐 English βš– 739 KB

## Abstract Adenoviruses are associated with endemic and epidemic acute conjunctivitis, large nosocomial outbreaks reflecting virus transmission on unwashed hands or inadequately sterilised ophthalmic instruments. The polymerase chain reaction (PCR) proved more sensitive than antigen detection by i

Highly sensitive detection of viral RNA
✍ Shigeki Murakami; Yoshiyuki Takahashi; Shigeru Yoshida; Isao Fuke; Kozo Ohmae; C πŸ“‚ Article πŸ“… 1994 πŸ› John Wiley and Sons 🌐 English βš– 722 KB

## Abstract A protocol was developed for a highly sensitive detection of viral RNA in blood specimens by reverse transcription coupled with a nested poly‐merase chain reaction. Using Japanese encephalitis virus (JEV) as a model, the optimized reverse transcription‐polymerase chain reaction (ORTPCR)