A generalized k-sampling scheme for 3D fast spin echo

โœ Scribed by Eugene G. Kholmovski; Dennis L. Parker; Andrew L. Alexander


Publisher
John Wiley and Sons
Year
2000
Tongue
English
Weight
250 KB
Volume
11
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

โœฆ Synopsis


The phase-encoding scheme can significantly affect the quality of fast spin-echo (FSE) images because the echo amplitude is modulated as a function of the echo position in k-space. The effects of the modulation in two-dimensional FSE imaging include ghosting and blurring artifacts and resolution loss in the phase-encoding (PE) direction. In 3D FSE imaging, the use of two PE directions presents the opportunity for improved PE schemes. A new scheme for assignment of echoes to views in 3D FSE, termed generalized, has been developed. This scheme distributes T 2 effects along both PE directions, allowing considerable flexibility in the selection of blurring artifact appearance. In a set of simulations, phantom experiments, and in vivo experiments, the performance of the generalized PE scheme for 3D FSE imaging was compared with the performance of existing PE schemes. The results demonstrate that the generalized PE scheme can be used to reduce blurring artifacts greatly relative to other PE techniques that are presently in use. This approach to PE can be used to manipulate the blurring artifact appearance and to optimize acquisition time.


๐Ÿ“œ SIMILAR VOLUMES


High resolution 3D imaging of the inner
โœ James N. Lee; Brian D. King; Dennis L. Parker; Henry R. Buswell; H. Ric Harnsber ๐Ÿ“‚ Article ๐Ÿ“… 1996 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 375 KB

A fast spin-echo pulse requence is described that producer high resolution images of the Inner ear Without suoceptibility artifacts. It uses thin overlapping slices that can be reformatted in multiple projections to provide a view of the 3D geometry of Inner ear structures, such aa the cochlea, vest

T2-weighted 3D fast spin echo imaging wi
โœ Ananth J. Madhuranthakam; Huanzhou Yu; Ann Shimakawa; Reed F. Busse; Martin P. S ๐Ÿ“‚ Article ๐Ÿ“… 2010 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 375 KB

## Abstract ## Purpose: To develop a robust 3D fast spin echo (FSE) T~2~โ€weighted imaging method with uniform water and fat separation in a single acquisition, amenable to highโ€quality multiplanar reformations. ## Materials and Methods: The Iterative Decomposition of water and fat with Echo Asym

A single-point dixon technique for fat-s
โœ Jingfei Ma ๐Ÿ“‚ Article ๐Ÿ“… 2008 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 504 KB

## Abstract ## Purpose To develop a singleโ€point Dixon (SPD) technique that requires only data of a single echo with a flexible echo time, and to demonstrate its use for fatโ€suppressed, T1โ€weighted contrast agent enhancement studies. ## Materials and Methods Raw data were collected using a produ

Processing of radial fast spin-echo data
โœ Maria I. Altbach; Ali Bilgin; Zhiqiang Li; Eric W. Clarkson; Theodore P. Trouard ๐Ÿ“‚ Article ๐Ÿ“… 2005 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 887 KB

## Abstract Radially acquired fast spinโ€echo data can be processed to obtain T~2~โ€weighted images and a T~2~ map from a single __k__โ€space data set. The general approach is to use data at a specific TE (or narrow TE range) in the center of __k__โ€space and data at other TE values in the outer part o

Fast high-resolution 3D segmented echo p
โœ Michael Lamba; Scott K. Holland; Vincent Schmithorst; Bernard Dardzinski; France ๐Ÿ“‚ Article ๐Ÿ“… 2003 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 351 KB

## Abstract The superheated emulsion chamber (SEC) consists of superheated droplets of halocarbons in an aqueous gel. The gel resides in a pressure chamber. Brachytherapy sources can be implanted in the SEC for radiation dosimetry studies. Upon irradiation by ionizing radiation, the metastable drop