๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

A fuzzy controller for activated sludge waste water plants

โœ Scribed by J Alex; U Jumar; R Tschepetzki


Publisher
Elsevier Science
Year
1994
Weight
616 KB
Volume
19
Category
Article
ISSN
0066-4138

No coin nor oath required. For personal study only.


๐Ÿ“œ SIMILAR VOLUMES


Possibilistic and fuzzy C-means clusteri
โœ Pekka Teppola; Pentti Minkkinen ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 304 KB ๐Ÿ‘ 1 views

A partial least squares (PLS) regression is used to model and visualize the waste-water treatment process. The score values of PLS are submitted to both a fuzzy C-means (FCM) clustering and a possibilistic C-means (PCM) clustering. In this work, four concepts are presented. Firstly, a hidden path pr

Application of a fuzzy controller in a w
โœ W.J.M. Kickert; H.R. Van Nauta Lemke ๐Ÿ“‚ Article ๐Ÿ“… 1976 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 630 KB

A new method of designing a controller, based on a vague kind of information and using fuzzy set theory, shows promising results in a case study. Seminary--In many cases a human operator is far more successful in controlling a complex industrial process than a controller designed by modern control

A thermophilic/mesophilic dual digestion
โœ R Roberts; Son Le; Cโ€ŠF Forster ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› Wiley (John Wiley & Sons) ๐ŸŒ English โš– 105 KB

Five conยฎgurations for a dual digestion were examined. The units were based on three 5 dm 3 completely stirred tank reactors (CSTR). A ยฎrst-stage thermophilic digester was used to provided the feed to each of the two second-stage mesophilic (35 ยฐC) digesters. The thermophilic digester was operated i

Activated sludge process coupled with in
โœ Oliver Jรคrvik; Andres Viiroja; Sven Kamenev; Inna Kamenev ๐Ÿ“‚ Article ๐Ÿ“… 2011 ๐Ÿ› Wiley (John Wiley & Sons) ๐ŸŒ English โš– 134 KB

## Abstract **BACKGROUND:** Ozone is applied in wastewater treatment for effluent water quality improvement (postโ€ozonation) as well as for excess sludge reduction (in the recirculation line). There is some evidence that ozone dosed directly to aerobic biooxidation (ABO) process enhances degradatio

Stochastic control for stabilization of
โœ R. Tenno; R. Vilu; H. Oit ๐Ÿ“‚ Article ๐Ÿ“… 1989 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 375 KB

A stochastic control law for the recycling flow of sludge which stabilizes the load characteristic of an aerotank near a given optimal level is proposed. It is shown that the mean square error of stabilization of the load characteristic using the control law proposed is three times less than in the