A thermophilic/mesophilic dual digestion system for treating waste activated sludge
✍ Scribed by R Roberts; Son Le; C F Forster
- Publisher
- Wiley (John Wiley & Sons)
- Year
- 1999
- Tongue
- English
- Weight
- 105 KB
- Volume
- 74
- Category
- Article
- ISSN
- 0268-2575
No coin nor oath required. For personal study only.
✦ Synopsis
Five con®gurations for a dual digestion were examined. The units were based on three 5 dm 3 completely stirred tank reactors (CSTR). A ®rst-stage thermophilic digester was used to provided the feed to each of the two second-stage mesophilic (35 °C) digesters. The thermophilic digester was operated initially at 55 °C with a hydraulic retention time of 4 h and then, later, at 60 °C with a hydraulic retention time of 3 h. The mesophilic digesters were operated at hydraulic retention times of 9, 12 and 15 days. In terms of volatile solids' (VS) reduction, the systems with a ®rst stage at 60 °C gave the better performance. However, based on the speci®c methane yield (m 3 CH 4 per kg VS removed), the con®guration with a ®rst stage operating at 55 °C and a secondary digester with a hydraulic retention time of 12 days was the most effective.