𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A Fiber-Optic Microarray Biosensor Using Aptamers as Receptors

✍ Scribed by Myoyong Lee; David R. Walt


Publisher
Elsevier Science
Year
2000
Tongue
English
Weight
81 KB
Volume
282
Category
Article
ISSN
0003-2697

No coin nor oath required. For personal study only.

✦ Synopsis


A fiber-optic biosensor using an aptamer receptor has been developed for the measurement of thrombin. An antithrombin DNA aptamer was immobilized on the surface of silica microspheres, and these aptamer beads were distributed in microwells on the distal tip of an imaging fiber. A different oligonucleotide bead type prepared using the same method as the aptamer beads was also included in the microwells to measure the degree of nonspecific binding. The imaging fiber was coupled to a modified epifluorescence microscope system, and the distal end of the fiber was incubated with a fluorescein-labeled thrombin (F-thrombin) solution. Nonlabeled thrombin could be detected using a competitive binding assay with F-thrombin. The aptamer beads selectively bound to the target and could be reused without any sensitivity change. The fiber-optic microarray system has a detection limit of 1 nM for nonlabeled thrombin, and each test can be performed in ca. 15 min including the regeneration time.


πŸ“œ SIMILAR VOLUMES


Detection of Clostridium botulinum toxin
✍ Robert A. Ogert; J. Edward Brown; Bal Ram Singh; Lisa C. Shriver-Lake; Frances S πŸ“‚ Article πŸ“… 1992 πŸ› Elsevier Science 🌐 English βš– 773 KB

A rapid, sensitive, analytical method for the detection of Clostridium botulinum toxin has been developed. The fiber optic-based biosensor utilizes the evanescent wave of a tapered optical fiber for signal discrimination. A 50 mW argon-ion laser, which generates laser light at 514 nm, is used in con

Determination of sulphite by use of a fi
✍ JΓ³zsef Hlavay; George G. Guilbault πŸ“‚ Article πŸ“… 1994 πŸ› Elsevier Science 🌐 English βš– 568 KB

A fiber-optic biosensor based on the immobilization of sulphite oxidase and peroxidase on different membranes, and subsequent detection of luminol chemiluminescence has been developed. The response was linear in the concentration ranges of 1 to 100 /\_LM and 3.2 to 320 PM, with a detection limit (si

An Electrochemical DNA Biosensor for the
✍ Nilay Aladag; Dilsat Ozkan-Ariksoysal; Duygu Gezen-Ak; Selma Yilmazer; Mehmet Oz πŸ“‚ Article πŸ“… 2010 πŸ› John Wiley and Sons 🌐 English βš– 268 KB πŸ‘ 2 views

## Abstract Electrochemical detection of nucleic acid base mismatches related to Apa I single nucleotide polymorphism (SNP) in the vitamin D receptor gene was performed successfully using 7‐dimethyl‐amino‐1,2‐benzophenoxazinium salt (Meldola's blue, MDB) with 10.9β€…pmol/100β€…ΞΌL of detection limit. MD