๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

A comparison of ligase chain reaction to polymerase chain reaction in the detection of Chlamydia trachomatis endocervical infections

โœ Scribed by J.D. Davis; P.K. Riley; C.W. Peters; K.H. Rand


Publisher
Hindawi Publishing Corporation
Year
1998
Tongue
English
Weight
57 KB
Volume
6
Category
Article
ISSN
1064-7449

No coin nor oath required. For personal study only.

โœฆ Synopsis


Objective:

To compare the reliability of ligase chain reaction (lcr) to polymerase chain reaction (pcr) in detecting chlamydia trachomatis endocervical infections.

Methods:

We conducted a prospective study of 486 patients at risk for chlamydial infection of the endocervix. we obtained two endocervical specimens from each patient and used lcr and pcr to detect c. trachomatis. discrepant results between the two techniques were resolved by repeat testing and by testing for the major outer membrane protein (momp) gene, if necessary. we determined the sensitivity, specificity, positive predictive value, and negative predictive value for each test, using concordant results or momp gene results as the "gold standard".

Results:

Of the 486 patients, 42 (8.6%) had evidence of c. trachomatis infection after resolution of discrepant results. of the 42 true positive specimens, 41 were positive by initial lcr and 38 were positive by initial pcr. of the 444 true negative specimens, none had a positive initial lcr result, while 2 had a positive initial pcr test. therefore, compared to the gold standard, lcr had a sensitivity of 97.6% and specificity of 100%, while pcr had a sensitivity of 90% and a specificity of 99.5%. the positive and negative predictive values of lcr were 100% and 99.8%, respectively. pcr had a positive predictive value of 95% and a negative predictive value of 99.1%. the difference in sensitivity of lcr versus pcr was not statistically significant (p = .125).

Conclusion:

Lcr and pcr perform equally well in detecting c. trachomatis endocervical infections.


๐Ÿ“œ SIMILAR VOLUMES


Performance of a commercial polymerase c
โœ C.H. Livengood III; K.A. Boggess; J.W. Wrenn; A.P. Murtha ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› Hindawi Publishing Corporation ๐ŸŒ English โš– 185 KB ๐Ÿ‘ 1 views

Objectives: To examine the accuracy of a commercial polymerase chain reaction (PCR) test (Amplicor CT R , Roche Diagnostic Systems, Branchburg NJ) for identification of endocervical chlamydial infections through both laboratory evaluation and among a diverse teaching hospital patient population. Me

Polymerase chain reaction assay with uri
โœ R. Pasternack; A. Mustila; P. Vuorinen; P.K. Heinonen; A. Miettinen ๐Ÿ“‚ Article ๐Ÿ“… 1996 ๐Ÿ› Hindawi Publishing Corporation ๐ŸŒ English โš– 54 KB ๐Ÿ‘ 2 views

Objective: The purpose of this study was to evaluate the benefits achievable by Amplicor polymerase chain reaction (PCR) (F. Hoffmann-LaRoche Ltd., Basel, Switzerland) with urine specimens in addition to PACE 2 (Gen-Probe, Inc., San Diego, California) assay with cervical swab specimens in the diagno

Utilization of polymerase chain reaction
โœ A. E. H. Merrie; K. Yun; J. L. McCall ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 137 KB ๐Ÿ‘ 2 views

Is Flow Cytometry a Useful Test? R epresenting a busy flow cytometry laboratory with an annual workload of approximately 1400 acute leukemia and malignant lymphoma cases, we read the article by Naughton et al. 1 with considerable interest. The authors concluded that "flow cytometry of bone marrow as

Utilization of polymerase chain reaction
โœ Ganesh V. Raj; Jose G. Moreno; Leonard G. Gomella ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 197 KB ๐Ÿ‘ 2 views

these detection assays require that a tumor have a significant volume of cancer cells. Advances in diagnostic techniques and technology may allow for cancer