A comparison of blind and lightwand-guided tracheal intubation through the intubating laryngeal mask
β Scribed by S. Kihara; S. Watanabe; N. Taguchi; A. Suga; J. R. Brimacombe
- Publisher
- John Wiley and Sons
- Year
- 2000
- Tongue
- English
- Weight
- 165 KB
- Volume
- 55
- Category
- Article
- ISSN
- 0003-2409
No coin nor oath required. For personal study only.
β¦ Synopsis
We have tested the hypothesis that intubation success rates, haemodynamic changes, airway complications and postoperative pharyngolaryngeal morbidity differ between blind and lightwand-guided intubation through the intubating laryngeal mask airway. One hundred and twenty paralysed anasthetised adult patients (ASA I-II, no known or predicted difficult airways) were assigned in a random manner to one of two equal-sized groups. In the blind group, patients were intubated blindly through the intubating laryngeal mask airway. In the lightwand group, patients were intubated through the intubating laryngeal mask airway assisted by transillumination of the neck with a lightwand. A standard sequence of adjusting manoeuvres was followed if resistance occurred during intubation or if transillumination was incorrect. The number of adjusting manoeuvres, time to intubation, intubation success rates, haemodynamic changes (pre-induction, pre-intubation, postintubation), oesophageal intubation, mucosal trauma (blood detected), hypoxia (oxygen saturation < 95%) and postoperative pharyngolaryngeal morbidity (double-blinded) were documented. Overall intubation success was similar (blind, 93%; lightwand, 100%), but time to successful intubation was significantly shorter (67 vs. 46 s, p = 0. 027) and the number of adjusting manoeuvres was significantly fewer (p = 0.024) in the lightwand group. There were no significant differences in blood pressure or heart rate between the groups at any time. Oesophageal intubation occurred more frequently in the blind group (18 vs. 0%, p = 0.002). The incidence and severity of mucosal injury, sore throat and hoarseness were similar between the groups. We conclude that lightwand-guided intubation through the intubating laryngeal mask is superior to the blind technique.
π SIMILAR VOLUMES
We conducted a prospective randomised study to compare the intubating laryngeal mask tracheal tube with a standard tube, for ease of tracheal intubation over a fibrescope. Thirtyβsix patients were investigated, using a sequential analysis technique. Ease of intubation was improved when the intubatin
We studied 40 anaesthetised and paralysed patients, in a randomised manner, to compare the ease of tracheal intubation either using a Macintosh laryngoscope and gum elastic bougie (group C) with the ease of tracheal intubation through the intubating laryngeal mask using a fibreoptic bronchoscope (gr
Seventy consecutive patients were randomly allocated for intubation through the intubating laryngeal mask airway using a straight reinforced silicone tracheal tube with either a conventional or a modified bevel. The conventional bevel was firm, wedgeβshaped and with a leading edge at the side. The m
Diffuse idiopathic skeletal hyperostosis, otherwise known as Forestier's disease or ankylosing hyperostosis, is a relatively common condition that is distinguished from ankylosing spondylitis by the relative preservation of spinal function and the characteristic βcandle flameβ lipping of the vertebr
Twenty-four inexperienced participants were timed inserting the intubating laryngeal mask airway and the laryngeal mask airway in 75 anaesthetised subjects. Adequacy of ventilation was assessed on a three-point scale. The pressure at which a leak first developed around the device's cuff was also mea