The ionization of nucleosides in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry was systematically investigated using adenine (A), thymine (T), guanine (G) and cytosine (C) with several common matrices. Experimental results of the protonation and deprotonation of the ba
A comparative study of a liquid and a solid matrix in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry and collision cross section measurements
β Scribed by Sven Ring; Yinon Rudich
- Publisher
- John Wiley and Sons
- Year
- 2000
- Tongue
- English
- Weight
- 80 KB
- Volume
- 14
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
β¦ Synopsis
We present experimental matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) results comparing a liquid (glycerol/K 4 [Fe(CN) 6 ]) and a solid matrix (2,5-dihydroxybenzoic acid, DHB) with respect to analyte signal stability and initial ion velocity. For applications requiring stable production of analyte ions over a long period of time, the liquid matrix is superior to the solid matrix. The stable analyte ion signal obtained from a liquid matrix allowed the measurement of collision cross sections of small poly(ethylene glycol) (PEG n ) adduct ions in the flight tube with good resolution. The initial velocity of these adduct ions was measured. It was found that analyte molecules from the liquid matrix have initial ion velocities significantly smaller than those from the solid matrix. MALDI-TOF measurements for large molecules using a liquid matrix are therefore likely to result in smaller systematic errors in mass calibrations due to initial ion velocity.
π SIMILAR VOLUMES
Chemical degradation methods combined with matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) and post-source decay (PSD)-MALDI reflex TOF mass spectrometry (MS) were used to determine the sequence of a peptide branched on to a known peptide backbone. This study was applied to a
The limits of performance of a linear time-of-flight mass spectrometer using matrix-assisted laser desorp tionlionization have been tested. Effects of the pressure in the vacuum system and the sampling rate of the digital oscilloscopes on mass resolution have been investigated. Spectra recorded at d
The time-of-flight effect in Fourier transform mass spectrometry (FTMS) with an external ion source was quantified. The time-of-flight profiles of ions of different masses were measured by stepping the time interval between the ionization pulse and the gating of the trapping voltage (T gate ). The o
This study presents matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) as a powerful tool to analyze and characterize oligonucleotides covalently linked to a solid support during their synthesis. The analysis of the fragment ions generated either in negative o