337 nm Matrix-assisted laser desorption/ionization of single aerosol particles
β Scribed by He, Lin; Murray, Kermit K.
- Publisher
- John Wiley and Sons
- Year
- 1999
- Tongue
- English
- Weight
- 86 KB
- Volume
- 34
- Category
- Article
- ISSN
- 1076-5174
No coin nor oath required. For personal study only.
β¦ Synopsis
Matrix-assisted laser desorption/ionization (MALDI) mass spectra were obtained from single particles injected directly into a time-of-flight mass spectrometer. Aerosol particles were generated at atmospheric pressure using a piezoelectric single-particle generator or a pneumatic nebulizer and introduced into the mass spectrometer through a series of narrow-bore tubes. Particles were detected by light scattering that was used to trigger a 337 nm pulsed nitrogen laser and the ions produced by laser desorption were mass separated in a two-stage reflectron time-of-flight mass spectrometer. MALDI mass spectra of single particles containing bradykinin, angiotensin II, gramicidin S, vitamin B 12 or gramicidin D were obtained at mass resolutions greater than 400 FWHM. For the piezoelectric particle generator, the efficiency of particle delivery was estimated to be βΌ0.02%, and 50 pmol of sample were consumed for each mass spectrum. For the pneumatic nebulizer, mass spectra could be obtained from single particles containing less than 100 amol of analyte, although the sample consumption for a typical mass spectrum was over 400 pmol.
π SIMILAR VOLUMES
On-line analysis of ultrafine aerosol particles in the 12 to 150 nm size range is performed by laser desorption/ionization. Particles are size selected with a differential mobility analyzer and then sent into a linear time-of-flight mass spectrometer where they are ablated with a 248 nm laser pulse.
A scheme of matrix ionization in UV matrix-assisted laser desorptiodionization is presented. Excitation to an upper lying electronic singlet state by the absorption of two photons and subsequent thermionic emission by vibronic coupling is proposed as the primary route for the formation of unprotonat
The application of an IR laser working at a wavelength of 3.27 mm, for matrix-assisted laser desorption/ ionization time-of-flight mass spectrometry and matrix-less laser desorption/ionization of different polymers, has been demonstrated. The ionization/desorption of polyethyleneglycols (PEG) and po
The ionization mechanisms in matrix-assisted laser desorption/ionization (MALDI) remain poorly understood. We have begun a program of study aimed at determining the properties of matrix molecules which make them suitable for MALDI. Initial results are presented here for one of the most widely used m
The effects of methanol, ethanol, propan-2-01 and acetonitrile on the aerosol matrix-assisted laser desorptionlionization (MALDI) ion signal of hradykinin, bovine insulin and myoglobin were examined. The effect of these solvents mixed with water was also studied. The aerosol MALDI ion signal for eac