𝔖 Bobbio Scriptorium
✦   LIBER   ✦

3-D heart image reconstructed from MRI data

✍ Scribed by Michiyoshi Kuwahara; Shigeru Eiho


Publisher
Elsevier Science
Year
1991
Tongue
English
Weight
464 KB
Volume
15
Category
Article
ISSN
0895-6111

No coin nor oath required. For personal study only.

✦ Synopsis


The gated MRI method gives us several sets of cross-sectional images on transverse, coronal, and sagittal planes of the heart in a cardiac cycle. In this paper, a method to reconstruct 3-D shapes of each part of the heart (i.e., left ventricle, left atrium, right ventricle, right atrium, aorta, and pulmonary artery), in a voxel space using these sets of cross-sectional images is proposed. The whole heart image composed of these six parts properly put together can be superimposed on the original cross-sectional images for display purposes.


πŸ“œ SIMILAR VOLUMES


3D ROI-image reconstruction from cone-be
✍ Dan Xia; Seungryong Cho; Junguo Bian; Yu Zou; Emil Y. Sidky; Nianming Zuo; Xiaoc πŸ“‚ Article πŸ“… 2007 πŸ› Elsevier Science 🌐 English βš– 820 KB

Helical and circular trajectories are expected to be adopted dominantly for data acquisition in X-ray cone-beam (CB) computed tomography (CT) imaging. However, non-conventional trajectories, such as tilted helical, saddle, circle-circle, and circle-line trajectories, may also find important applicat

Quantitative 3D reconstruction from BS i
πŸ“‚ Article πŸ“… 2004 πŸ› Elsevier Science 🌐 English βš– 908 KB

The well known technique for separately enhancing topographic and compositional contrast in BS images has been refined. The underlying quantitative theory has been developed, both for acquisition and processing, and tested first in the optical field. The surprisingly good results moved to return to

New strategy for reconstructing partial-
✍ Xiaodong Zhang; Essa Yacoub; Xiaoping Hu πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 146 KB

## Abstract Most partial Fourier (PF) approaches use a low‐resolution phase estimate in the reconstruction to account for non‐zero phases of the image. These methods may fail when there are large phase errors, a situation commonly encountered in __T__‐weighted functional MRI (fMRI). To mitigate thi

Reconstructing MR images from undersampl
✍ James G. Pipe πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 315 KB

Data which are sampled more densely than the Nyquist limit in k-space are weighted prior to reconstruction by the inverse of the local sampling density. This work considers the effects of weighting data that are sampled less densely than the Nyquist limit. It specifically analyzes azimuthally unders