✦ Synopsis
The wear resistance of stabilized zirconias was investigated on both a pin-on-disk machine and a Dangoumeau apparatus under dry and lubricated (water) conditions. Under the experimental conditions (80 N load and I2 mm/s speed) the wear mechanism can be described as initial plastic deformation and then grain pull-out. The role of the third-body in the interJlace of friction has been demonstrated with asymmetric couples where one of the antagonists is made qf alumina. If for pure friction it is not easy to differentiate the magnesia partially stabilized zirconias (MgPSZ) from the yttria tetragonal zirconia polycrystal ( YTZP), after shock tests we can conclude that the YTZP have a better wear behaviour than the MgPSZ, especially in the case of attrition applications.
📜 SIMILAR VOLUMES
Wear and friction are often minimized at sliding contacts in moving equipment parts by the use of lubricants. These lubricants become more and more unwanted for environmental and maintenance reasons. This causes an increased interest in the development of ceramic materials with stable sliding contac