𝔖 Bobbio Scriptorium
✦   LIBER   ✦

VUV Single-Photon Ionization Ion Trap Time-of-Flight Mass Spectrometer for On-Line, Real-Time Monitoring of Chlorinated Organic Compounds in Waste Incineration Flue Gas

✍ Scribed by Kuribayashi, Shizuma; Yamakoshi, Hideo; Danno, Minoru; Sakai, Satoshi; Tsuruga, Shigenori; Futami, Hiroshi; Morii, Shigeki


Book ID
126783547
Publisher
American Chemical Society
Year
2005
Tongue
English
Weight
207 KB
Volume
77
Category
Article
ISSN
0003-2700

No coin nor oath required. For personal study only.


πŸ“œ SIMILAR VOLUMES


On-line measurement of chlorobenzene in
✍ Ralf Zimmermann; Hans JΓΆrg Heger; Martin Blumenstock; Ralph Dorfner; Karl-Werner πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 217 KB πŸ‘ 2 views

Mobile resonance-enhanced multiphoton ionization time-of-flight mass spectrometry (REMPI-TOFMS) was applied for on-line detection of surrogates for polychlorinated dibenzo-p-dioxins/furans (PCDD/F) in the flue gas of an industrial hazardous waste incineration plant (thermal power: 22 MW). Convention