## Abstract ## Purpose To improve 3D volume‐selective turbo spin echo (TSE) carotid artery wall imaging by incorporating navigators to reduce artifacts caused by swallowing. ## Materials and Methods Images were acquired on a Siemens Magnetom Sonata 1.5T scanner. 3D volume‐selective TSE scans of
Volume-selective 3D turbo spin echo imaging for vascular wall imaging and distensibility measurement
✍ Scribed by Lindsey A. Crowe; Peter Gatehouse; Guang Zhong Yang; Raad H. Mohiaddin; Anitha Varghese; Clare Charrier; Jennifer Keegan; David N. Firmin
- Publisher
- John Wiley and Sons
- Year
- 2003
- Tongue
- English
- Weight
- 749 KB
- Volume
- 17
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Purpose
To use a volume‐selective 3D turbo spin echo (TSE) technique to image the carotid artery wall and measure distensibility.
Materials and Methods
A high‐resolution volume‐selective 3D TSE sequence has been developed. Volume selection is accomplished by orthogonal gradients for the 90° and 180° excitations and allows a 3D volume of vessel wall to be imaged in a relatively short time. The technique has been developed to allow imaging at any defined phase of the cardiac cycle so that the vascular function and distensibility can be studied.
Results
Scan efficiency is increased by the reduced phase encode field of view (FOV) (k~y~ steps) by the use of selective volume excitation. Significantly more slices (k~z~ phase encode steps) for vessel coverage can be acquired with the same scan time as that of the conventional sequence while maintaining signal‐to‐noise ratio (SNR) levels. The practical value of the technique was demonstrated on 10 normal subjects with high‐resolution vessel distensibility measurements of the carotid arteries.
Conclusion
A volume‐selective TSE method has been used for carotid artery wall imaging and measurement of distensibility in normal subjects. Larger coverage of the vessel, and therefore more information for clinical diagnostics, was achieved with the same overall scan time with an SNR comparable to that of 2D full FOV images. J. Magn. Reson. Imaging 2003;17:572–580. © 2003 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract ## Purpose To improve three‐dimensional (3D) volume‐selective turbo spin‐echo (TSE) carotid wall imaging by the addition of a novel body surface swallowing detection device. ## Material and Methods A 3D volume‐selective TSE sequence was used to image the carotid artery. A novel carbo
## Abstract Single‐slab 3D turbo/fast spin echo (SE) imaging with very long echo trains was recently introduced with slab selection using a highly selective excitation pulse and short, nonselective refocusing pulses with variable flip angles for high imaging efficiency. This technique, however, is
## Abstract __T__~1~‐weighted contrast is conventionally obtained using multislice two‐dimensional (2D) spin‐echo (SE) imaging. Achieving isotropic, high spatial resolution is problematic with conventional methods due to a long acquisition time, imperfect slice profiles, or high‐energy deposition.
## Abstract ## Purpose To compare a volume‐selective three‐dimensional turbo spin echo (TSE) technique with ultrasound (US) for assessing carotid artery wall structure and function. ## Materials and Methods A three‐dimensional volume‐selective TSE technique was used to image the carotid artery i
## Abstract Conventional __T__~2~‐weighted turbo/fast spin echo imaging is clinically accepted as the most sensitive method to detect brain lesions but generates a high signal intensity of cerebrospinal fluid (CSF), yielding diagnostic ambiguity for lesions close to CSF. Fluid‐attenuated inversion