On page 44, column 1, line 31, a reference was inadvertently not included. The line should read ''. . . A new sulfonyl fluoride derivative, PSF, was synthesized and tested for its inhibitory activity for AEA amidase as reported earlier (14) . . .'' instead of ''. . . A new sulfonyl fluoride derivati
Volume determination of TEM specimens containing particles or precipitates
โ Scribed by Hare, Thomas M. ;Russ, John C. ;Lane, Jay E.
- Publisher
- Wiley (John Wiley & Sons)
- Year
- 1988
- Tongue
- English
- Weight
- 491 KB
- Volume
- 10
- Category
- Article
- ISSN
- 0741-0581
No coin nor oath required. For personal study only.
โฆ Synopsis
The volume of thin foil specimens, which contain precipitate or other particles, viewed in the TEM is needed to determine particle density and spacing. It can be determined from the locations of the particles, measured using stereo pairs. A calculation that determines the volume between planes (not necessarily parallel or horizontal) that enclose the points is described. These planes will systematically underestimate the actual surface spacing and hence the volume, but a simple correction factor based on the number of points used in the fit can be used to estimate the actual volume. The method is tested, and its accuracy is evaluated using simulated data and applied to precipitate particles in creep-tested silicon carbide.