Voltammetric characterization of a graphite-teflon electrode
β Scribed by Klatt, Leon N.; Connell, Don R.; Adams, Robert E.; Honigberg, Irwin L.; Price, James C.
- Book ID
- 125503589
- Publisher
- American Chemical Society
- Year
- 1975
- Tongue
- English
- Weight
- 373 KB
- Volume
- 47
- Category
- Article
- ISSN
- 0003-2700
No coin nor oath required. For personal study only.
π SIMILAR VOLUMES
## Abstract Amperometric biosensors incorporating tyrosinase into Teflon/graphite composite were developed for the detection of catechol. The homogeneity of Teflon/graphite was elucidated by means of chronoamperometry (using ferricyanide) and the calculation of the electrochemically active and tota
The mechanical and chemical stabxlity of Teflon \* bonded graphite electrodes operating in the oxygen evolution mode in 5N KOH was studied as a function of cd and time. The electrode starts to break up at 13 mA cm-' and on subsequent cathodic oxygen reduction performance is greatly reduced. Moreover