𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Visualising fouling of a chromatographic matrix using confocal scanning laser microscopy

✍ Scribed by Sun Chau Siu; Rihab Boushaba; Vithaya Topoyassakul; Alex Graham; Sorwar Choudhury; Guy Moss; Nigel J. Titchener-Hooker


Publisher
John Wiley and Sons
Year
2006
Tongue
English
Weight
225 KB
Volume
95
Category
Article
ISSN
0006-3592

No coin nor oath required. For personal study only.

✦ Synopsis


Confocal scanning laser microscopy (CSLM) was used to visualise the spatial location of foulants during the fouling of Q Sepharose FF matrix in finite batch experiments and for examining the subsequent effectiveness of clean-in-place (CIP) treatments in cleaning the heavily fouled beads. Beads were severely fouled with partially clarified E. coli homogenate by contacting the beads with the foulant for contact times of 5 min, 1 or 12 h. The use of two different fluorescent dyes, PicoGreen and Cy5.5, for labelling genomic PicoGreen-labelled dsDNA and protein respectively, allowed the direct observation of the chromatographic beads. The extent of fouling was assessed by measuring the subsequent adsorption of Cy5.5-labelled BSA to the beads. Control studies established that the labelling of BSA did not affect significantly the protein properties. In the control case of contacting the unfouled matrix with Cy5.5-labelled BSA, protein was able to penetrate the entire matrix volume. After fouling, Cy5.5-labelled BSA was unable to penetrate the bead but only to bind near the bead surface where it slowly displaced PicoGreen-conjugated dsDNA, which bound only at the exterior of the beads. Labelled host cell proteins bound throughout the bead interior but considerably less at the core; suggesting that other species might have occupied that space. The gross levels of fouling achieved drastically reduced the binding capacity and maximum Cy5.5-labelled BSA uptake rate. The capacity of the resin was reduced by 2.5-fold when incubated with foulant for up to 1 h. However, when the resin was fouled for a prolonged time of 12 h a further sixfold decrease in capacity was seen. The uptake rate of Cy5.5-labelled BSA decreased with increased fouling time of the resin. Incubating the fouled beads in 1 M NaCl dissociated PicoGreen-labelled dsDNA from the bead exterior within 15 min of incubation but proved ineffective in removing all the foulant protein. Cy5.5-labelled BSA was still unable to bind beyond the outer region of the beads. A harsher CIP treatment of 1 M NaCl dissolved in 1 M NaOH was also ineffective in removing all the foulant protein but did remove PicoGreen-conjugated dsDNA within 15 min of incubation. Cy5.5-labelled BSA was able to bind throughout the bead interior after this more aggressive CIP treatment but at a lower capacity than in the case of fresh beads. The competitive adsorption of BacLight Red-labelled whole cells or cell debris and PicoGreen-conjugated dsDNA was also visualised using CSLM.


πŸ“œ SIMILAR VOLUMES


A study of hydrogenated carbon fibers by
✍ Antonio MadroΓ±ero De La Cal; Juan Aguado-Serrano; Maria Luisa Rojas-Cervantes; E πŸ“‚ Article πŸ“… 2009 πŸ› John Wiley and Sons 🌐 English βš– 349 KB

## Abstract The hydrogen absorption process is studied in carbonaceous fibers produced from a mixture of methane and hydrogen. The absorption of the hydrogen was examined in two types of fibers, in β€œas‐grown” state and after a process of desorption during an annealing to 1.473 K under vacuum. Later

Determination of Structure of Aggregates
✍ A. Thill; S. Veerapaneni; B. Simon; M. Wiesner; J.Y. Bottero; D. Snidaro πŸ“‚ Article πŸ“… 1998 πŸ› Elsevier Science 🌐 English βš– 107 KB

The fractal dimension of a particle aggregate can provide fundamental information on the structure and origin of the aggregate. The analysis of large chemically homogeneous fractal objects has been achieved, but reliable methods of estimating the fractal dimensions of large and chemically heterogene

Confocal laser scanning microscopy of ca
✍ Stricker, Stephen A.; Whitaker, Michael πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 614 KB

Confocal laser scanning microscopy (CLSM) is widely used to monitor intracellular calcium levels in living cells loaded with calcium-sensitive fluorophores. This review examines the basic advantages and limitations of CLSM in in vivo imaging analyses of calcium dynamics. The benefits of utilizing ra

Investigation of single protein adsorpti
✍ M Ahmed; D L Pyle πŸ“‚ Article πŸ“… 1999 πŸ› Wiley (John Wiley & Sons) 🌐 English βš– 174 KB πŸ‘ 2 views

Currently there are many ion exchangers available for protein puriΓΌcation, but there is little information on how efficiently the ion exchanger surface is used for protein binding. In this work we present the results from a confocal scanning laser microscope study of two anion exchangers, DEAE Toyop