Purpose:

To investigate the feasibility of a vessel size imaging (VSI) technique with separate contrast agent injections for evaluation of the vessel caliber in normal tissues and in brain tumors.

Materials and Methods:

Computer simulation was first performed to assess the potential errors in the estimation of vessel caliber that could result from time shifts between the dual contrast agent injections. Eight patients (four female, four male, 37–77 years old) with brain tumors (three high‐grade gliomas, two low‐grade gliomas, and three meningiomas) were recruited for clinical study. Dynamic susceptibility contrast magnetic resonance imaging (MRI) using gradient echo (GE) and spin echo (SE) echo‐planar imaging sequences were performed separately with a 10‐minute interval on a 3.0T scanner. Vessel caliber maps were calculated and analyzed in regions of interest at cortical gray matter (GM), thalamus, white matter (WM), and tumors.

Results:

From the computer simulation, the error of vessel caliber measurement was less than 8% when the difference between the time‐to‐peak of the GE and the SE studies was 1.5 seconds, and reduced to within 5% when the difference was 1 second. From the patient datasets of a 64 × 64 matrix, the estimated vessel calibers were 37.4 ± 12.9 μm for cortical gray matter, 20.7 ± 8.8 μm for thalamus, and 15.0 ± 5.1 μm for white matter, comparable to results in the literature. Two patients had a VSI with 128 × 128 matrix and showed similar results in vessel calibers of normal tissues. All the tumors had larger mean vessel diameter than normal‐appearing tissues. The difference in vascular size between normal tissue and tumor was demonstrated clearly in both the VSIs of regular and high spatial resolution.

Conclusion:

This study suggests that VSI with a dual injection method is a feasible technique for estimating microvascular calibers of normal tissues and brain tumors in clinical scanners. J. Magn. Reson. Imaging 2009;30:1078–1084. © 2009 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Dual contrast GRASE (gradient-spin echo)
✍ David A. Feinberg; Berthold Kiefer; Andrew W. Litt 📂 Article 📅 1994 🏛 John Wiley and Sons 🌐 English ⚖ 471 KB

## Abstract Equal time spacing of RF pulses in the CPMG sequence imposes a constraint of equal signal read periods in spin‐echo train imaging. GRASE imaging differs by using multiple read gradients in each π‐π time interval, which are not constrained to be equal in number or duration. This addition

Enhanced positive-contrast visualization
✍ Parker H. Mills; Eric T. Ahrens 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 337 KB

## Abstract Iron oxide–based MRI contrast agents are increasingly being used to noninvasively track cells, target molecular epitopes, and monitor gene expression in vivo. Detecting regions of contrast agent accumulation can be challenging if resulting contrast is subtle relative to endogenous tissu