𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Vessel-encoded dynamic magnetic resonance angiography using arterial spin labeling

✍ Scribed by Thomas W. Okell; Michael A. Chappell; Mark W. Woolrich; Matthias Günther; David A. Feinberg; Peter Jezzard


Publisher
John Wiley and Sons
Year
2010
Tongue
English
Weight
404 KB
Volume
64
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A new noninvasive MRI method for vessel selective angiography is presented. The technique combines vessel‐encoded pseudocontinuous arterial spin labeling with a two‐dimensional dynamic angiographic readout and was used to image the cerebral arteries in healthy volunteers. Time‐of‐flight angiograms were also acquired prior to vessel‐selective dynamic angiography acquisitions in axial, coronal, and/or sagittal planes, using a 3‐T MRI scanner. The latter consisted of a vessel‐encoded pseudocontinuous arterial spin labeling pulse train of 300 or 1000 ms followed by a two‐dimensional thick‐slab flow‐compensated fast low angle shot readout combined with a segmented Look‐Locker sampling strategy (temporal resolution = 55 ms). Selective labeling was performed at the level of the neck to generate individual angiograms for both right and left internal carotid and vertebral arteries. Individual vessel angiograms were reconstructed using a bayesian inference method. The vessel‐selective dynamic angiograms obtained were consistent with the time‐of‐flight images, and the longer of the two vessel‐encoded pseudocontinuous arterial spin labeling pulse train durations tested (1000 ms) was found to give better distal vessel visibility. This technique provides highly selective angiograms quickly and noninvasively that could potentially be used in place of intra‐arterial x‐ray angiography for larger vessels. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Vessel-encoded dynamic magnetic resonanc
✍ Thomas W. Okell; Michael A. Chappell; Mark W. Woolrich; Matthias Günther; David 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 379 KB

## Abstract A new noninvasive MRI method for vessel‐selective angiography is presented. The technique combines vessel‐encoded pseudocontinuous arterial spin labeling with a two‐dimensional dynamic angiographic readout and was used to image the cerebral arteries in healthy volunteers. Time‐of‐flight

Vessel-encoded arterial spin-labeling us
✍ Eric C. Wong 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 474 KB

## Abstract A new signal‐to‐noise ratio (SNR) efficient method is introduced for the mapping of vascular territories based on pseudocontinuous arterial spin labeling (ASL). A pseudocontinuous tagging pulse train is modified using additional transverse gradient pulses and phase cycling to place some

In vivo estimation of the flow-driven ad
✍ Ruth L. O'Gorman; Paul E. Summers; Fernando O. Zelaya; Steven C. R. Williams; Da 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 323 KB 👁 1 views

## Abstract The accurate quantification of perfusion with arterial spin labeling (ASL) requires consideration of a number of factors, including the efficiency of the inversion and control pulses used for spin labeling. In this study the effects of spin velocity on continuous ASL efficiency when usi