Study objective: To examine the validity of a disposable, colorimetric end-tidal CO 2 detector in verifying endotracheal tube (ETT) placement in infants and children. Design: The detector was studied prospectively in 151 intubations. Setting: Operating room, ICU, and emergency department of a chil
โฆ LIBER โฆ
Verifying endotracheal tube placement in children
โ Scribed by D Higgins; FC Anaes
- Publisher
- Elsevier Science
- Year
- 1992
- Tongue
- English
- Weight
- 82 KB
- Volume
- 21
- Category
- Article
- ISSN
- 1097-6760
No coin nor oath required. For personal study only.
๐ SIMILAR VOLUMES
Validity of a disposable end-tidal CO2 d
โ
Mananda S Bhende; Ann E Thompson; D Ryan Cook; Alvin L Saville
๐
Article
๐
1992
๐
Elsevier Science
๐
English
โ 327 KB
Ultrasound confirmation of endotracheal
โ
David T. Raphael; Frederick U. Conard III
๐
Article
๐
1987
๐
John Wiley and Sons
๐
English
โ 403 KB
Real-time B-mode ultrasound imaging was performed in 24 intubated patients in order to confirm the correct placement of endotracheal tubes. The large acoustic impedance mismatch between the air within the endotracheal tube cuff and the tracheal wall could be bypassed by (1) use of a foam-cuffed Bivo
Should cuffed endotracheal tubes be used
โ
Robin G. Cox
๐
Article
๐
2005
๐
Springer-Verlag
๐
French
โ 50 KB
An unusual cause of difficulty confirmin
โ
Arie Peliowski; Chris Christodoulou
๐
Article
๐
2003
๐
Springer-Verlag
๐
French
โ 74 KB
Intubation depth markings allow an impro
โ
Markus Weiss; Christian Balmer; Alexander Dullenkopf; Walter Knirsch; Andreas Ch
๐
Article
๐
2005
๐
Springer-Verlag
๐
French
โ 494 KB
Videolaryngoscopy for tracheal intubatio
โ
Georges L. Savoldelli; Eduardo Schiffer
๐
Article
๐
2008
๐
Springer-Verlag
๐
French
โ 47 KB