Vascular response to laser photothermolysis as a function of pulse duration, vessel type, and diameter: Implications for port wine stain laser therapy

✍ Scribed by Sol Kimel; Lars O. Svaasand; Danielle Cao; Marie J. Hammer-Wilson; J. Stuart Nelson


Publisher
John Wiley and Sons
Year
2002
Tongue
English
Weight
321 KB
Volume
30
Category
Article
ISSN
0196-8092

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Background and Objective

Treatment of port wine stains (PWS) by photothermolysis can be improved by optimizing laser parameters on an individual patient basis. We have studied the critical role of pulse duration (t~p~) on the treatment efficacy.

Study Design/Materials and Methods

The V‐beam laser (Candela) allowed changing t~p~ over user‐specified discrete values between 1.5 and 40 milliseconds by delivering a series of 100 microsecond spikes. For the 1.5 and 3 millisecond pulses, three spikes were observed at intervals t~p~/2 and for t~p~ ≥ 6 milliseconds, four spikes separated by t~p~/3. The ScleroPlus laser (Candela) has a smooth output over its fixed 1.5 milliseconds duration. Blood vessels in the chick chorioallantoic membrane (CAM) were irradiated at fixed wavelength (595 nm), spot size (7 mm), radiant exposure (15 Jcm^−2^), and at variable t~p~. The CAM contains an extensive microvascular network ranging from capillaries with diameter D < 30 μm to blood vessels of D ≈ 120 μm. The CAM assay allows real‐time video documentation, and observation of blood flow in pre‐capillary arterioles (A) and post‐capillary venules (V). Vessel injury was graded from recorded videotapes. Mathematical modeling was developed to interpret results of vessel injury when varying t~p~ and D. A modified thermal relaxation time was introduced to calculate vessel wall temperature following laser exposure.

Results

Arterioles. For increasing t~p~, overall damage was found to decrease. For fixed t~p~, damage decreased with vessel size. Venules. For all D, damage was smaller than for corresponding arterioles. There was no dependence of damage on t~p~. For given t~p~, no variation of damage with D was observed. Photothermolysis due to spiked (V‐beam) vs. smooth (Scleroplus) delivery of laser energy at fixed t~p~ (1.5 milliseconds), showed similar vessel injuries for al values of D (P>0.05).

Conclusions

The difference between initial arteriole and venule damage could be explained by the threefold higher absorption coefficient at 595 nm in (oxygen‐poor!) arterioles. In human patients, PWS consist of ectatic venules (characterized by higher absorption), so that these considerations favor the use of 595‐nm irradiation for laser photothermolysis. For optimal treatment of PWS it is proposed that t~p~ be between 0.1 and 1.5 milliseconds. This is based on a modified relaxation time τ~d~′, defined as the time required for heat conduction into the full thickness of the vessel wall, which is assumed to have a thickness Δ__D__ ≈ 0.1__D.__ The corresponding τ~d~′ will be a factor of about six smaller than given in the literature. For vessels with D between 30 and 300 μm, τ~d~′ ranges from 0.1 to 1.5 milliseconds. Lasers Surg. Med. 30:160–169, 2002. © 2002 Wiley‐Liss, Inc.