Utility of laboratory studies in the emergency department patient with a new-onset seizure
β Scribed by Timothy L Turnbull; Todd L Vanden Hoek; David S Howes; Robin F Eisner
- Publisher
- Elsevier Science
- Year
- 1990
- Tongue
- English
- Weight
- 501 KB
- Volume
- 19
- Category
- Article
- ISSN
- 1097-6760
No coin nor oath required. For personal study only.
β¦ Synopsis
Extensive laboratory testing is often performed in the emergency department evaluation of the new-onset seizure patient. To determine the utility of such testing, a prospective study of patients with a new-onset seizure presenting to the ED of an inner-city, university-affiliated teaching hospital was done. One hundred thirty-six patients were entered into the study between October 1984 and January 1988. All patients had uniform data collection performed. Pertinent historical information and physical examination findings were recorded on a standardized form before laboratory analysis was available on CBC, electrolytes, BUN, creatinine, glucose, calcium, and magnesium levels. In 11 cases (8%), a correctable laboratory abnormality was a sole or contributory cause of the seizure disorder. These included four patients with hypoglycemia, four with hyperglycemia, two with hypocalcemia, and one with hypomagnesemia. Only two cases (hypoglycemia) were not suspected on the basis of findings on the history or physical examination. In ED patients, the incidence of a new-onset seizure due to a correctable metabolic disturbance is low. We conclude that, with the exception of the serum glucose, the extensive ED laboratory workup often done for the evaluation of a new-onset seizure is unnecessary. Further test ordering should be directed by the medical history and physical examination.
π SIMILAR VOLUMES
## Abstract Acute flank pain is a frequent clinical presentation encountered in emergency departments, and a workβup for obstructive urolithiasis in this setting is a common indication for computed tomography (CT). However, imaging alternatives to CT for the evaluation of renal colic are warranted
## Abstract Patients with unstable angina pectoris and acute myocardial infarction have higher than normal Dβdimer levels. The aim of the study was to determine the value of the Dβdimer test in patients with unstable angina pectoris and a normal electrocardiogram on presentation at the emergency de
Cytopenia is a common problem in hematology outpatient clinics and among hospitalized patients. A bone marrow (BM) aspirate and biopsy are often performed to rule out an infiltrative versus intrinsic BM process, such as myelodysplastic syndrome (MDS). We have previously described a flow cytometric (