In dynamic MRI, it is often difficult to achieve the acquisition speed required to resolve or freeze the temporal variations of the imaged object. Several MRI methods aim at speeding up the image acquisition process. Through assumptions and/or prior knowledge, these dynamic MRI methods allow part of the needed data to be calculated instead of acquired. For example, partial-Fourier imaging assumes that phase varies smoothly within the object, and parallel imaging (e.g., simultaneous acquisition of spatial harmonics (SMASH) and sensitivity encoding (SENSE)) uses prior knowledge about receiver-coil sensitivity. While these methods accelerate acquisition, they can introduce artifacts or amplify noise in doing so. The present work aims at accelerating image acquisition significantly, while introducing almost no artifacts or noise amplification. It is shown here that new, extra information is gained if dynamic MRI methods are modified so that the sampling function changes in specific ways from time-frame to time-frame. In other words, the set of k-space locations that are acquired (instead of calculated) changes with time. The present temporal strategy, based on the UNaliasing by Fourier-encoding the Overlaps in the temporaL Dimension (UNFOLD) method, can be incorporated into common dynamic MRI methods. Results with partial-Fourier, SMASH, and SENSE imaging are presented here, where UNFOLD's contribution is to very significantly reduce the artifact and/or amplified noise content. Used in this way, UNFOLD contributes indirectly, rather than directly to the improvement in image acquisition speed, as it allows companion methods to operate properly at greater acceleration settings than would otherwise be feasible.
π SIMILAR VOLUMES
## Abstract ## Purpose To compare image quality, artifacts, and signalβtoβnoise ratio (SNR) in cardiac cine TrueFISP magnetic resonance imaging (MRI) with and without parallel acquisition techniques (PAT). ## Materials and Methods MRI was performed in 16 subjects with a TrueFISP sequence (1.5 T;
## Abstract Resolution in ^1^H lung imaging is limited mainly by the acquisition time. Today, halfβFourier acquisition singleβshot turbo spinβecho (HASTE) sequences, with short echo time (TE) and short interecho spacing (T~inter~) have found increased use in lung imaging. In this study, a HASTE seq
## Abstract Two data sets for halfβFourier imaging (HFI) can be collected in the same time as one data set for conventional full Fourier imaging (FFI). The hypothesis is that averaging twice as much data in HFI does not make ghost artifacts caused by motion have less signal intensity than in FFI. T
## Abstract This article presents a method to reconstruct liver MRI data acquired continuously during free breathing, without any external sensor or navigator measurements. When the deformations associated with __k__βspace data are known, generalized matrix inversion reconstruction has been shown t