Using UNFOLD to remove artifacts in parallel imaging and in partial-Fourier imaging

✍ Scribed by Bruno Madore


Publisher
John Wiley and Sons
Year
2002
Tongue
English
Weight
965 KB
Volume
48
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


In dynamic MRI, it is often difficult to achieve the acquisition speed required to resolve or freeze the temporal variations of the imaged object. Several MRI methods aim at speeding up the image acquisition process. Through assumptions and/or prior knowledge, these dynamic MRI methods allow part of the needed data to be calculated instead of acquired. For example, partial-Fourier imaging assumes that phase varies smoothly within the object, and parallel imaging (e.g., simultaneous acquisition of spatial harmonics (SMASH) and sensitivity encoding (SENSE)) uses prior knowledge about receiver-coil sensitivity. While these methods accelerate acquisition, they can introduce artifacts or amplify noise in doing so. The present work aims at accelerating image acquisition significantly, while introducing almost no artifacts or noise amplification. It is shown here that new, extra information is gained if dynamic MRI methods are modified so that the sampling function changes in specific ways from time-frame to time-frame. In other words, the set of k-space locations that are acquired (instead of calculated) changes with time. The present temporal strategy, based on the UNaliasing by Fourier-encoding the Overlaps in the temporaL Dimension (UNFOLD) method, can be incorporated into common dynamic MRI methods. Results with partial-Fourier, SMASH, and SENSE imaging are presented here, where UNFOLD's contribution is to very significantly reduce the artifact and/or amplified noise content. Used in this way, UNFOLD contributes indirectly, rather than directly to the improvement in image acquisition speed, as it allows companion methods to operate properly at greater acceleration settings than would otherwise be feasible.


πŸ“œ SIMILAR VOLUMES


Parallel acquisition techniques in cardi
✍ Peter Hunold; Stefan Maderwald; Mark E. Ladd; Vladimir Jellus; JΓΆrg Barkhausen πŸ“‚ Article πŸ“… 2004 πŸ› John Wiley and Sons 🌐 English βš– 385 KB πŸ‘ 1 views

## Abstract ## Purpose To compare image quality, artifacts, and signal‐to‐noise ratio (SNR) in cardiac cine TrueFISP magnetic resonance imaging (MRI) with and without parallel acquisition techniques (PAT). ## Materials and Methods MRI was performed in 16 subjects with a TrueFISP sequence (1.5 T;

Resolution enhancement in lung 1H imagin
✍ R.M. Heidemann; M.A. Griswold; B. Kiefer; M. Nittka; J. Wang; V. Jellus; P.M. Ja πŸ“‚ Article πŸ“… 2003 πŸ› John Wiley and Sons 🌐 English βš– 341 KB

## Abstract Resolution in ^1^H lung imaging is limited mainly by the acquisition time. Today, half‐Fourier acquisition single‐shot turbo spin‐echo (HASTE) sequences, with short echo time (TE) and short interecho spacing (T~inter~) have found increased use in lung imaging. In this study, a HASTE seq

Ineffectiveness of averaging for reducin
✍ Michael L. Wood πŸ“‚ Article πŸ“… 1991 πŸ› John Wiley and Sons 🌐 English βš– 731 KB

## Abstract Two data sets for half‐Fourier imaging (HFI) can be collected in the same time as one data set for conventional full Fourier imaging (FFI). The hypothesis is that averaging twice as much data in HFI does not make ghost artifacts caused by motion have less signal intensity than in FFI. T

Motion artifact correction in free-breat
✍ M. J. White; D. J. Hawkes; A. Melbourne; D. J. Collins; C. Coolens; M. Hawkins; πŸ“‚ Article πŸ“… 2009 πŸ› John Wiley and Sons 🌐 English βš– 377 KB

## Abstract This article presents a method to reconstruct liver MRI data acquired continuously during free breathing, without any external sensor or navigator measurements. When the deformations associated with __k__‐space data are known, generalized matrix inversion reconstruction has been shown t