Use of the constant-volume bomb technique for measuring burning velocity

โœ Scribed by R.C. Eschenbach; J.T. Agnew


Publisher
Elsevier Science
Year
1958
Tongue
English
Weight
688 KB
Volume
2
Category
Article
ISSN
0010-2180

No coin nor oath required. For personal study only.

โœฆ Synopsis


The method for computing normal burning velocity, called S u, [rom observed data in constant-volume bomb measurements is developed from first principles. The theory accounts approximately for effects due to the finite velocity of sound, and shows how radius~time measurements may he used to determine S, for quite fast-burning mtxtares. It is shown that the degree of completeness of combustion, important in computing S,,, cannot be determined with any accuracy from homb data, even with simultaneous pressure and radius measurement. Experimental apparatus suitable for constant-volume bomb work at super-atmospheric initial pressures is described, and measurements of [tame speed are reported for a stoichiometric methane-,oxygen mixture for pressures from 0"1 to 2 atmospheres. Values of S,, computed from the data on flame speed are in fair agreement with values obtained by burner methods.


๐Ÿ“œ SIMILAR VOLUMES


Laminar burning velocity of acetylene-ai
โœ C.J. Rallis; A.M. Garforth; J.A. Steinz ๐Ÿ“‚ Article ๐Ÿ“… 1965 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 726 KB

One o[ the main purposes of this paper has been to provide an evaluation of the spherical constant volume vessel method with particular reference to its use over the full range of the combustion process. To this end basic equations, as well as a variety of corroborative relations, applicable through

Modification of the drop dialysis techni
โœ L.D. Taylor; W.F. Burke Jr. ๐Ÿ“‚ Article ๐Ÿ“… 1989 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 161 KB

Desalting of nucleic acids by the drop dialysis method is limited by the fact that only small volume samples can be used due to the lack of sample containment on the membrane filters. A specially modified Styrafoam cup can be used as a membrane filter holder which serves to contain the sample, thus