𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Use of piezoelectric pressure transducers to determine local solids mass flux in the riser of a cold flow circulating fluidized bed

✍ Scribed by James L. Spenik; J. Christopher Ludlow


Publisher
Elsevier Science
Year
2010
Tongue
English
Weight
846 KB
Volume
203
Category
Article
ISSN
0032-5910

No coin nor oath required. For personal study only.

✦ Synopsis


A method to determine local mass flux measurements within the riser of a circulating fluidized bed using the rate of impingement of particles on the surface of a piezoelectric pressure transducer is described. Statistically designed experiments with various solids circulation rates and riser gas velocities were conducted in the riser of a cold flow circulating fluidized bed to verify the accuracy of the method. Also, various techniques to relate the impingement rate to mass flux were employed. It is believed that this method delivers results in situations where more standard methods, such as isokinetic sampling, fail.