๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Use of literature values of temperature programmed retention indexes in qualitative analysis by isothermal gas chromatography

โœ Scribed by Takeda, Ichiro


Publisher
John Wiley and Sons
Year
1991
Tongue
English
Weight
400 KB
Volume
14
Category
Article
ISSN
0935-6304

No coin nor oath required. For personal study only.

โœฆ Synopsis


Abstract

Numerous reports have appeared on the determination of temperature programmed retention indexes in gas chromatography and although chromatographic variables should be completely consistent with published data if such indexes are to be of use, the reproduction of such rigorous parameters is quite difficult. This report presents an approximate method for using published values of temperature programmed retention indexes in isothermal chromatography.

In general, the temperature dependence of the isothermal retention indexes of a number of compounds can be expressed as a series of oblique lines on a plot with retention index as the abscissa and temperature as the ordinate; the elution order of the compounds at a given, isothermal, temperature is then indicated by the points at which the compounds' oblique lines cut the horizontal line corresponding to the temperature of interest.

In linear temperature programmed chromatography, the horizontal line representing isothermal operation becomes, to a first approximation, a sloping line with a gradient corresponding to the programming rate: this has been verified experimentally and may be valid over a wide range of temperatures. This line can be used to predict isothermal retention indexes for use in qualitative analysis.


๐Ÿ“œ SIMILAR VOLUMES


Retention indices in the analysis of foo
โœ Federica Bianchi; Maria Careri; Alessandro Mangia; Marilena Musci ๐Ÿ“‚ Article ๐Ÿ“… 2007 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 397 KB ๐Ÿ‘ 1 views

## Abstract A retention index (RI) database containing 250 volatile compounds was created on a polar stationary phase column and validated for food aroma characterisation. Precision of the retention indices (RIs) was assessed by performing replicated injections of a representative number of volatil

Gas chromatography: Elution temperature,
โœ W.G. Jennings; S. Adam ๐Ÿ“‚ Article ๐Ÿ“… 1975 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 466 KB

The elution temperatures and degree of separation of a model system series of hydrocarbons were followed as functions of the rate of temperature programming and carrier gas velocity. Graphs are presented that permit individual assessment of these variables. Lower elution temperatures can be achieved