✦ Synopsis


Abstract

This in vivo study evaluated the fixation of two types of titanium implants with the use of an injectable calcium‐phosphate (CaP) cement. The cement was either used to create a cement mantle (Type A implant) or as an additive to press‐fit placed titanium plasma sprayed implants (Type B implant). The implants were placed in trabecular bone of the medial femoral condyle of goats and left in place for 2 and 10 weeks. Mechanical evaluation of the implant fixation was done by torque testing. This showed that for the Type A implants the calcium‐phosphate cement's performance was significantly inferior (P < 0.05) to that of polymethylmethacrylate cement fixation. For the two‐week Type B implants a significant increase (P < 0.05) in failure load was found for calcium‐phosphate cemented implants compared with just press‐fitted Type B implants. Histological evaluation revealed that for Type A implants, failure during torque testing occurred at the implant–cement interface. In contrast, for Type B implants, failure occurred in the bone–implant interface for press‐fit–placed devices and in the cement layer for CaP‐cemented devices. Further, the CaP cement was found to be overgrown with new formed bone already after 2 weeks of implantation. The cement showed resorption due to regular bone remodeling. On the basis of these observations, it was concluded that the use of injectable CaP cement might facilitate earlier loading of press‐fit inserted titanium implants. Nevertheless, the results have to be confirmed in dynamical mechanical as well as loaded in vivo studies. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 66B: 447–456, 2003


📜 SIMILAR VOLUMES


Prophylaxis of infection and effects on
✍ Dirk Jan F. Moojen; H. Charles Vogely; André Fleer; Peter G.J. Nikkels; Paul A. 📂 Article 📅 2009 🏛 Elsevier Science 🌐 English ⚖ 299 KB 👁 2 views

## Abstract No options are available for local antibiotic delivery from uncemented implants. By loading a porous titanium implant with a biomimetic HA‐coating (PeriApatite, PA) with antibiotics, we could obtain adequate local antibiotic concentrations and reduce infection susceptibility. This study

The influence of the acidic component of
✍ Saeed Hesaraki; Ali Zamanian; Fatollah Moztarzadeh 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 387 KB 👁 1 views

## Abstract In the present study, macroporous calcium phosphate cements (CPCs) were prepared using a porogen; that is, the gas‐foaming technique. The objective was to investigate the influence of the acidic component of the porogen (acetic acid __versus__ citric acid) on several properties of a spe