𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Use of high-performance liquid chromatography to detect hydroxyl and superoxide radicals generated from mitomycin C

✍ Scribed by Chris A. Pritsos; Panayiotis P. Constantinides; Thomas R. Tritton; David C. Heimbrook; Alan C. Sartorelli


Publisher
Elsevier Science
Year
1985
Tongue
English
Weight
463 KB
Volume
150
Category
Article
ISSN
0003-2697

No coin nor oath required. For personal study only.

✦ Synopsis


Distinguishing between short-lived reactive oxygen species like hydroxyl and superoxide radicals is difficult; the most successful approaches employ electron spin resonance (ESR) spin-trapping techniques. Using the spin trap 5,5-dimethyl-l-pyrroline N-oxide (DMPO) to selectively trap various radicals in the presence and absence of ethanol, an HPLC system which is capable of separating the hydroxyl- and superoxide-generated DMPO adduct species has been developed. The radical-generated DMPO adducts were measured with an electrochemical detector attached to the HPLC system and confirmed by spin-trapping techniques. The HPLC separation was carried out on an ODS reverse-phase column with a pH 5.1 buffered 8.5% acetonitrile mobile phase. The advantage of the HPLC system described is that it permits the separation and detection of hydroxyl and superoxide radicals without requiring ESR instrumentation. The antineoplastic bioreductive alkylating agent mitomycin C, when activated by NADPH-cytochrome c reductase, was shown to generate both hydroxyl and superoxide radicals.


πŸ“œ SIMILAR VOLUMES


A high-performance liquid chromatography
✍ Kenneth S. Bauer; Richard M. Lush; Michelle A. Rudek; Carolyn Shih; Edward Sausv πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 70 KB πŸ‘ 2 views

UCN-01, 7-hydroxystaurosporine, is an antagonist of protein kinase C, as well as causing cell cycle arrest. We developed and validated an HPLC assay method for the quantitation of UCN-01. Plasma and saliva standard curves were prepared at concentrations ranging from 0.2 to 20.0 mg/mL and 4.0 to 200.

The use of combined high performance liq
✍ E. Houghton; M. C. Dumasia; J. K. Wellby πŸ“‚ Article πŸ“… 1981 πŸ› John Wiley and Sons 🌐 English βš– 582 KB

Negative ion chemical ionization mass spectra of some corticosteroids have been obtained by direct syringe introduction on to the Finnigan moving belt high-performance liquid chromatograph-mass spectrometer interface. Proprietary preparations based upon dexamethasone, betamethasone and prednisolone