Use of crosslinked poly(ferric acrylate) as a sorbent in solid-phase extraction

โœ Scribed by K. Sreenivasan


Publisher
John Wiley and Sons
Year
2002
Tongue
English
Weight
77 KB
Volume
83
Category
Article
ISSN
0021-8995

No coin nor oath required. For personal study only.


๐Ÿ“œ SIMILAR VOLUMES


Determination of pesticide residues in c
โœ Pengyue Zhao; Lei Wang; Jinhui Luo; Jianguo Li; Canping Pan ๐Ÿ“‚ Article ๐Ÿ“… 2011 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 163 KB

## Abstract A modified quick, easy, cheap, effective, rugged and safe (QuEChERS) method with multiโ€walled carbon nanotubes (MWCNTs) as a reversedโ€dispersive solidโ€phase extraction (rโ€DSPE) material combined with gas chromatographyโ€mass spectrometry was developed for the determination of 14 pesticid

Application of multiwalled carbon nanotu
โœ Pei Liang; Qiong Ding; Feng Song ๐Ÿ“‚ Article ๐Ÿ“… 2005 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 95 KB

## Abstract The adsorption behavior of multiwalled carbon nanotubes (MWNTs) toward copper has been investigated systemically, and a new method has been developed for the determination of trace copper in water samples based on preconcentration with a microcolumn packed with MWNTs prior to its determ

Magnesium oxide microspheres as a novel
โœ Jing Jin; Zhiping Zhang; Jincheng Wang; Peipei Qi; Jiping Chen ๐Ÿ“‚ Article ๐Ÿ“… 2010 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 238 KB

## Abstract Magnesium oxide microspheres were developed as a novel SPE sorbent for the determination of benzo[a]pyrene (BaP), one of the most potent carcinogenic agents, in environmental water samples. The parameters controlling the extraction efficiency, such as elution volume, flow rate, pH value

Solid-phase microextraction using pencil
โœ Hai Bin Wan; Hua Chi; Ming Keong Wong; Chup Yew Mok ๐Ÿ“‚ Article ๐Ÿ“… 1994 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 648 KB

Most solid-phase microextraction methods are based on sly ~d~ethyls~oxane)-moated silica fibers. In the present study, pencil lead was used as an alternative sorbent for solid-phase microextraction. Its application to three organic pollutants with different polarity in water was investigated. The de

Automated analysis of the pyridinium cro
โœ David A. Pratt; Yuri Daniloff; Alexander Duncan; Simon P. Robins ๐Ÿ“‚ Article ๐Ÿ“… 1992 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 845 KB

A fully automated method for assaying the collagen crosslinking amino acids, pyridinoline and deoxypyridinoline, in human urine samples or tissue hydrolysates is described. Samples were processed using a Gilson ASPEC system with solid-phase extraction of the crosslinks on columns containing 100 mg o