๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Use of bioimpedance for measuring cardiac output in the conscious dog

โœ Scribed by Michael J. DePasquale; Anthony A. Fossa


Publisher
John Wiley and Sons
Year
1996
Tongue
English
Weight
891 KB
Volume
38
Category
Article
ISSN
0272-4391

No coin nor oath required. For personal study only.

โœฆ Synopsis


Cardiovascular profiling of developmental compounds by General Pharmacology/ Safety Pharmacology is an integral part of the drug discovery process in support of registration of clinical candidates. Non-invasive screening tools which provide hemodynamic measurements can facilitate the drug development process. One such method, bioimpedance cardiography, is an indirect means of evaluating cardiac output. Changes in thoracic impedance in response to an applied current are related to changes in volume and velocity of blood flow in the thorax for the determination of stroke volume, which is coupled to heart rate for calculating cardiac output. Commercially available bioimpedance cardiography units have evolved considerably in recent years in step with advances in computing power. The use of these units, with modification, in the preclinical arena for determinations in anesthetized dogs and pigs has shown good correlation with other accepted methodologies for measuring cardiac output. Data presented here are the first to describe the application of this technology in conscious dogs. The utility and limitations of this method as a screening tool in the conscious dog are discussed. These cardiac output measurements combined with arterial pressure and electrocardiogram measurements, provide a simple means for more complete hemodynamic profiling of drug candidates. o 1% WiIey-Liss, Inc.


๐Ÿ“œ SIMILAR VOLUMES


Application of the thermodilution techni
โœ Burnett, Louis E. ;de Fur, Peter L. ;Jorgensen, Darwin D. ๐Ÿ“‚ Article ๐Ÿ“… 1981 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 731 KB

## Abstract A thermodilution technique is used to measure the flow of hemolymph through the heart of crabs. The technique consists of injecting a small volume of cold filtered sea water into the ventricle and monitoring temperature changes with time in an artery immediately downstream from the hear

Use of assumed versus measured oxygen co
โœ Wolf, Andreas ;Pollman, Matthew J. ;Trindade, Pedro T. ;Fowler, Michael B. ;Alde ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 176 KB

Assumed oxygen consumption (VO 2 ) is increasingly used as a convenient surrogate for measured VO 2 for calculation of cardiac output. This substitution is often based on empirical formulae, previously validated only in relatively young patients. To assess the inaccuracy introduced by extrapolating

A program in Quickbasic for the estimati
โœ Ronald E. De Meersman ๐Ÿ“‚ Article ๐Ÿ“… 1988 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 202 KB

The current program in Quickbasic provides a valid and reliable computational method for the estimation of cardiac output, using the CO2 rebreathe method. In addition, this program will save time through speed of execution. Furthermore, the program can be used with IBM microcomputers as well as IBM

Use of cardiac output to improve measure
โœ Jeff L. Zhang; Henry Rusinek; Louisa Bokacheva; Qun Chen; Pippa Storey; Vivian S ๐Ÿ“‚ Article ๐Ÿ“… 2009 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 488 KB

## Abstract ## Purpose To validate a new method for converting MR arterial signal intensity versus time curves to arterial input functions (AIFs). ## Materials and Methods The method constrains AIF with patient's cardiac output (Q). Monte Carlo simulations of MR renography and tumor perfusion pr