Use of a 3 French system for balloon aortic valvuloplasty in infants

✍ Scribed by Dennis W. Kim; Anthony A. Raviele; Robert N. Vincent


Publisher
John Wiley and Sons
Year
2005
Tongue
English
Weight
57 KB
Volume
66
Category
Article
ISSN
1522-1946

No coin nor oath required. For personal study only.

✦ Synopsis


For infants with valvar aortic stenosis, balloon aortic valvuloplasty has supplanted surgical valvotomy as the initial treatment of choice at most institutions. Technological innovations have resulted in further miniaturization of balloon dilation catheters, allowing this procedure to be performed through smaller sheath sizes. Currently, the Tyshak-Mini balloon dilation catheter (B. Braun Medical) allows passage of up to an 8 mm dilation balloon catheter through a 3 Fr hemostatic sheath. The efficacy of this system for the treatment of valvar aortic stenosis in infants less than 6 months of age was evaluated in 20 patients undergoing 22 procedures. Mean age at the time of intervention was 26 6 46 days. Mean transvalvar gradient was 76 6 22 mm Hg prior to balloon dilation. Following balloon valvuloplasty, residual gradient was 26 6 12 mm Hg, reflecting a mean change in peak-to-peak gradient of 49 6 19 mm Hg. Postintervention increase in aortic insufficiency was one grade or less in 19/22 procedures, two grades in 2 procedures, and three grades in 1 procedure. There were no significant vascular complications reported immediately following the procedure. Repeat valvuloplasty was performed in three patients in which the 3 Fr system was used in two patients. The 3 Fr system for balloon aortic valvuloplasty in infants less than 6 months of age is effective and safe.


πŸ“œ SIMILAR VOLUMES


Use of a low-profile, compliant balloon
✍ Eric Yamen; David V. Daniels; HoHai Van; Alan C. Yeung; William F. Fearon πŸ“‚ Article πŸ“… 2009 πŸ› John Wiley and Sons 🌐 English βš– 285 KB

## Abstract Objectives: To determine the safety and immediate efficacy after balloon aortic valvuloplasty (BAV) with a new, low‐profile balloon. Background: BAV has a continuing role in the management of high‐risk patients with severe aortic stenosis (AS). BAV with traditional noncompliant balloons

Use of a percutaneous arterial suture de
✍ Andrew D. Michaels; Thomas A. Ports πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 38 KB πŸ‘ 1 views

## Abstract Percutaneous balloon aortic valvuloplasty has been used as a therapeutic option for patients with severe aortic stenosis who are not candidates for aortic valve replacement. This procedure has been limited by both the high rate of aortic valve restenosis and high procedural morbidity re

Functional anatomy of the cardiovascular
✍ E. Robert Burns πŸ“‚ Article πŸ“… 2008 πŸ› John Wiley and Sons 🌐 English βš– 89 KB πŸ‘ 2 views

## Abstract Preadolescent students are interested in learning the structure and function of the human body. However, their teachers are not trained in this content. The purpose of this project was to expand a successful outreach effort in the health sciences for grade 7–12 teachers to include PreK‐