𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Ultrashort TE imaging with off-resonance saturation contrast (UTE-OSC)

✍ Scribed by Jiang Du; Atsushi M. Takahashi; Mark Bydder; Christine B. Chung; Graeme M. Bydder


Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
260 KB
Volume
62
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Short T~2~ species such as the Achilles tendon and cortical bone cannot be imaged with conventional MR sequences. They have a much broader absorption lineshape than long T~2~ species, therefore they are more sensitive to an appropriately placed off‐resonance irradiation. In this work, a technique termed ultrashort TE (UTE) with off‐resonance saturation contrast (UTE‐OSC) is proposed to image short T~2~ species. A high power saturation pulse was placed +1 to +2 kHz off the water peak to preferentially saturate signals from short T~2~ species, leaving long T~2~ water and fat signals largely unaffected. The subtraction of UTE images with and without an off‐resonance saturation pulse effectively suppresses long T~2~ water and fat signals, creating high contrast for short T~2~ species. The UTE‐OSC technique was validated on a phantom, and applied to bone samples and healthy volunteers on a clinical 3T scanner. High‐contrast images of the Achilles tendon and cortical bone were generated with a high contrast‐to‐noise ratio (CNR) of the order of 12 to 20 between short T~2~ and long T~2~ species within a total scan time of 4 to 10 min. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Magnetic resonance imaging with ultrasho
✍ Damian J. Tyler; Matthew D. Robson; R. Mark Henkelman; Ian R. Young; Graeme M. B 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 634 KB

## Abstract It is now possible to detect signals from tissues and tissue components with short T~2~s, such as cortical bone, using ultrashort TE (UTE) pulse sequences. The background to the use of these sequences is reviewed with particular emphasis on MR system issues. Tissue properties are discus

Magnetic resonance imaging of the liver
✍ Karyn E. Chappell; Nayna Patel; Peter D. Gatehouse; Janice Main; Basant K. Puri; 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 263 KB

## Purpose: To assess the feasibility of imaging the liver in volunteers and patients with ultrashort echo time (ute) pulse sequences. ## Materials and methods: Seven normal controls as well as 12 patients with biopsy-proven generalized liver disease and three patients with focal disease were exa

Magnetization transfer imaging with puls
✍ Joseph C. McGowan; III; Mitchell D. Schnall; John S. Leigh 📂 Article 📅 1994 🏛 John Wiley and Sons 🌐 English ⚖ 426 KB

## Abstract Magnetization transfer contrast (MTC) can be generated in magnetic resonance images of water‐containing macromolecular structures. Results obtained with the pulsed off‐resonance saturation technique for achieving MTC are presented, allowing comparison of this technique with others. The