For the production of ultrahigh vacuum in an unbaked vacuum system the effect of helium glow discharge cleaning as a wall conditioning technique has been investigated experimentally. A test chamber made of 304 stainless steel was constructed. Before the pump-down of the chamber it was initialized by
The effect of neon glow discharge cleaning (GDC) on the reduction of water outgassing and the production of ultrahigh vacuum was studied using a 304 stainless steel chamber. Two pumping systems having different effective pumping speeds of 10 l s\ and 182 l s\ were used. By switching these pumping sy