Verrucarol is a simple trichothecene which is structurally related to T-2 and HT-2 toxins. Several macrocyclic trichothecenes which are ester derivatives of verrucarol possess antitumor activity. The pharmacokinetics of verrucarol has been studied in eight dogs following iv and oral administrations
Trichothecene mycotoxins in the dust of ventilation systems in office buildings
β Scribed by Wanda Smoragiewicz; Bruno Cossette; Armel Boutard; Krzysztof Krzystyniak
- Publisher
- Springer-Verlag
- Year
- 1993
- Tongue
- English
- Weight
- 487 KB
- Volume
- 65
- Category
- Article
- ISSN
- 0340-0131
No coin nor oath required. For personal study only.
β¦ Synopsis
Analysis of trichothecene mycotoxins in dust samples from ventilation systems of office buildings was applied as a rapid and inexpensive method for the detection of mycotoxins. Dust samples from three different office spaces of the Montreal urban area, reportedly affected by the "sick buildings syndrome", were analysed by thin-layer chromatography (TLC). Positive colour reaction on TLC plates with 4-(p-nitrobenzyl) pyridine, specific for the 12,13-epoxy group in the trichothecene nucleus, was obtained for the extracts of 0.5- to 50-g dust samples. The dust samples contained at least four trichothecenes: T-2 toxin, diacetoxyscirpenol, roridine A and T-2 tetraol. The results were confirmed by high-performance liquid chromatography analysis. Screening of dust samples from air ventilation systems of reportedly affected buildings provided direct evidence of trichothecene mycotoxins, with the detection limit estimated as 0.4-4 ng/mg dust. Thus, the dust sample analysis is suggested as a rapid technique for detecting the presence of myotoxins in the dust of ventilation systems.
π SIMILAR VOLUMES
## Abstract Phaseβsensitive nuclear Overhauser enhancement spectroscopy (NOESY) experiments, ^3^__J__ couplings and computational molecular modeling (MM2\* and MMFF force fields) were employed to examine the conformational properties of verrucarin A in chloroform solutions. The MMFF force field cal
This paper presents the energy performance of office buildings in Montreal based on a survey of 68 buildings (2.5 million square metres). The results indicate an average annual normalized energy consumption of 502.2 kWh/(meyr) and an average annual normalized energy cost of 19.5 $/(m2yr). The electr
Dust has been implicated as a major contributor to the increased incidence of respiratory disorders among pig workers. Unlike gaseous contaminants, dust is not uniformly distributed within pig buildings. Dust spatial distribution is an important variable in the understanding of dust transportation a