Tribology and total hip joint replacement: Current concepts in mechanical simulation
✍ Scribed by S. Affatato; M. Spinelli; M. Zavalloni; C. Mazzega-Fabbro; M. Viceconti
- Publisher
- Elsevier Science
- Year
- 2008
- Tongue
- English
- Weight
- 576 KB
- Volume
- 30
- Category
- Article
- ISSN
- 1350-4533
No coin nor oath required. For personal study only.
✦ Synopsis
Interest in the rheology and effects of interacting surfaces is as ancient as man. This subject can be represented by a recently coined word: tribology. This term is derived from the Greek word "tribos" and means the "science of rubbing". Friction, lubrication, and wear mechanism in the common English language means the precise field of interest of tribology. Wear of total hip prosthesis is a significant clinical problem that involves, nowadays, a too high a number of patients. In order to acquire further knowledge on the tribological phenomena that involve hip prosthesis wear tests are conducted on employed materials to extend lifetime of orthopaedic implants. The most basic type of test device is the material wear machine, however, a more advanced one may more accurately reproduce some of the in vivo conditions. Typically, these apparatus are called simulators, and, while there is no absolute definition of a joint simulator, its description as a mechanical rig used to test a joint replacement, under conditions approximating those occurring in the human body, is acceptable. Simulator tests, moreover, can be used to conduct accelerated protocols that replicate/simulate particularly extreme conditions, thus establishing the limits of performance for the material. Simulators vary in their level of sophistication and the international literature reveals many interpretations of the design of machines used for joint replacement testing. This paper aims to review the current state of the art of the hip joint simulators worldwide. This is specified through a schematic overview by describing, in particular, constructive solutions adopted to reproduce in vivo conditions. An exhaustive commentary on the evolution and actually existing simulation standards is proposed by the authors. The need of a shared protocol among research laboratories all over the world could lead to a consensus conference.
📜 SIMILAR VOLUMES
## Abstract A case of osseous reankylosis occurred after total replacement of one hip in a patient having ankylosing spondylitis. Not only did the ankylotic disease involve the vertebral column, but the severity of this process had been manifest through osseous ankylosis of bilateral cup arthroplas
Ultra-high molecular weight polyethylene (UHMWPE) wear particles play a significant role in failures of total joint replacements (TJRs). In this work, we investigated the distribution of these wear particles in periprosthetic tissues obtained from nine revisions of hip TJR. In the first step, all pe
## Abstract The mechanical and tribological properties of a new biomaterial, an ultra high molecular weight polyethylene–hyaluronan (UHMWPE‐HA) microcomposite, were investigated in this article, which is Part II of a two‐part study. Part I presented the synthesis and physical/chemical characterizat
## Abstract ## Objective To evaluate factors influencing orthopedic surgeons' decision in daily practice to recommend or not recommend total hip arthroplasty (THA) in patients with hip osteoarthritis (OA). ## Methods General practitioners and rheumatologists were asked to prospectively include 1