𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Treatment of resistant tattoos using a new generation Q-switched Nd:YAG laser: Influence of beam profile and spot size on clearance success

✍ Scribed by Syrus Karsai; Gudrun Pfirrmann; Stefan Hammes; Christian Raulin


Publisher
John Wiley and Sons
Year
2008
Tongue
English
Weight
155 KB
Volume
40
Category
Article
ISSN
0196-8092

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Background and Objectives

Multiple treatments of resistant tattoos often result in fibrosis and visible textural changes that lessen response to subsequent treatments. The aim of this study is to evaluate the influence of beam profile and spot size on clearance rates and side effects in the setting of resistant tattoos.

Study Design/Material and Methods

Thirty‐six professional, black tattoos (32 patients) were treated unsuccessfully with a Q‐switched Nd:YAG laser (MedLite™ C3, HoyaConBio Inc., Fremont, CA). Because of therapy resistance all tattoos were re‐treated using a new generation Nd:YAG laser (MedLite™ C6, HoyaConBio Inc.). Maximum energy fluence (E
~max~), mean energy fluence, mean spot size, level of clearance, side effects and beam profile (irradiance distribution) of both laser systems were assessed and evaluated in a retrospective study.

Results

All tattoos were previously treated with the C3 laser at 1,064 nm using a mean E~max~ of 5.8±0.8 J/cm^2^ (range 3.8–7.5 J/cm^2^) as compared with a mean E~max~ of 6.4±1.6 J/cm^2^ (range 3.2–9.0 J/cm^2^) during the C6 treatment course. Corresponding spot sizes were larger during C6 treatments as compared with C3 (5.0±0.9 and 3.6±0.2 mm, respectively). The C6 laser had a “flat top” and homogenous profile regardless of the spot size. For the C3 laser the beam shape was “Gaussian,” and the homogeneity was reduced by numerous micro‐spikes and micro‐nadirs.

After the C6 treatment course 33.3% of the tattoos showed clearance of grade 1 (0–25%), 16.7% of grade 2 (26–50%), 16.7% of grade 3 (51–75%), 30.5% of grade 4 (76–95%), 2.8% of grade 5 (96–100%). The total rate of side effects due to C6 treatment was 8.3% in all tattoos (hyperpigmentation 5.6%, hypopigmentation 2.7%, textural changes/scars 0%).

Conclusion

This clinical study documents for the first time the impact of a 1,064‐nm Nd:YAG laser with a more homogenous beam profile and a larger spot size on the management of resistant tattoos. Only a few treatment sessions were necessary to achieve an additional clearance with a low rate of side effects. Lesers Surg. Med. 40:139–145, 2008. © 2008 Wiley‐Liss, Inc.