๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Transit delay and flow quantification in muscle with continuous arterial spin labeling perfusion-MRI

โœ Scribed by Wen-Chau Wu; Jiongjiong Wang; John A. Detre; Sarah J. Ratcliffe; Thomas F. Floyd


Publisher
John Wiley and Sons
Year
2008
Tongue
English
Weight
644 KB
Volume
28
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

โœฆ Synopsis


Abstract

Purpose

To test the hypothesis that flow measurements using continuous arterial spin labeling (CASL) magnetic resonance imaging (MRI) in muscle depend upon transit delay, and examine the repeatability of CASL measurements.

Materials and Methods

A total of 23 healthy subjects underwent CASL imaging of the calf, foot, and forearm with varying postlabeling delay (PLD = 1000, 1500, and 1900 msec). Experiments were conducted on a 3.0T system. An orthopedic tourniquet system was employed to create a fiveโ€minute period of ischemia followed by a transient hyperemic flow. Imaging commenced two minutes prior to cuff inflation and ended three minutes after cuff release.

Results

CASL was found able to well resolve the time course of the hyperemic flow pattern with an effective TR of 16 seconds, although we were unable to establish that a plateau had been reached in the flow measurements even at a PLD as long as 1900 msec. Peak hyperemic flow measurements compared favorably with those obtained with contrastโ€enhanced (CE) MRI following a similar period of ischemia. Regionโ€ofโ€interest (ROI)โ€“based repeated measurements varied by approximately 20% over a period of one hour.

Conclusion

In all anatomic regions studied, flow measurements were found to increase with PLD, suggesting the prolonged transit delay in muscle. J. Magn. Reson. Imaging 2008;28:445โ€“452. ยฉ 2008 Wileyโ€Liss, Inc.


๐Ÿ“œ SIMILAR VOLUMES


Estimation of perfusion and arterial tra
โœ Danny J. J. Wang; Xiaoming Bi; Brian B. Avants; Tongbai Meng; Sven Zuehlsdorff; ๐Ÿ“‚ Article ๐Ÿ“… 2010 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 329 KB

## Abstract Arterial spin labeling (ASL) provides noninvasive measurement of tissue blood flow, but sensitivity to motion has limited its application to imaging of myocardial blood flow. Although different cardiac phases can be synchronized using electrocardiography triggering, breath holding is ge

In vivo assessment of absolute perfusion
โœ Jรถrg U.G. Streif; Karl-Heinz Hiller; Christiane Waller; Matthias Nahrendorf; Fra ๐Ÿ“‚ Article ๐Ÿ“… 2002 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 257 KB

## Abstract ## Purpose To assess absolute perfusion in the skeletal muscle of mice in vivo with spin labeling magnetic resonance imaging (MRI) under normal and stress conditions. ## Materials and Methods Absolute perfusion in the skeletal muscle of 27 C57BL/6 mice was assessed in vivo nonโ€invasi

Multislice continuous arterial spin-labe
โœ Hirohiko Kimura; Hirotsugu Kado; Yoshio Koshimoto; Tatsurou Tsuchida; Yoshiharu ๐Ÿ“‚ Article ๐Ÿ“… 2005 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 626 KB

## Abstract ## Purpose To compare the use of multislice continuous arterial spin labeling (CASL) and CO~2~ positron emission tomography (PET) to assess CBF in patients with chronic occlusive cerebrovascular disease for the validation of quantitative CASL perfusion in an altered hemodynamic state.