๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Transient response of a magnetoelectroelastic solid with two collinear dielectric cracks under impacts

โœ Scribed by Xian-Ci Zhong; Fang Liu; Xian-Fang Li


Publisher
Elsevier Science
Year
2009
Tongue
English
Weight
525 KB
Volume
46
Category
Article
ISSN
0020-7683

No coin nor oath required. For personal study only.

โœฆ Synopsis


Dynamic analysis of two collinear electro-magnetically dielectric cracks in a piezoelectromagnetic material is made under in-plane magneto-electro-mechanical impacts. Generalized semi-permeable crackface boundary conditions are proposed to simulate realistic opening cracks with dielectric. Ideal boundary conditions of a combination of electrically permeable or impermeable and magnetically permeable or impermeable assumptions are several limiting cases of the semi-permeable dielectric crack. Utilizing the Laplace and Fourier transforms, the mixed initial-boundary-value problem is reduced to solving singular integral equations with Cauchy kernel. Dynamic intensity factors of stress, electric displacement, magnetic induction and crack opening displacement (COD) near the inner and outer crack tips are determined in the Laplace transform domain. Numerical results for a special magnetoelectroelastic solid are calculated to show the influences of the dielectric permittivity and magnetic permeability inside the cracks on the crack-face electric displacement and magnetic induction. By means of a numerical inversion of the Laplace transform, the variations of the normalized intensity factors of stress and COD are discussed against applied magnetoelectric impact loadings and the geometry of the cracks for fully impermeable, vacuum, fully permeable cracks and shown in graphics.


๐Ÿ“œ SIMILAR VOLUMES


Transient response of an interfacial cra
โœ W.J. Feng; Y.S. Li; Z.H. Xu ๐Ÿ“‚ Article ๐Ÿ“… 2009 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 706 KB

The dynamic response of an interfacial crack between two dissimilar magnetoelectroelastic layers is investigated under magnetic, electrical and mechanical impact loadings. Four kinds of ideal crack-face assumptions, i.e., magnetoelectrically impermeable (Case 1), magnetically impermeable and electri